Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
SG330

SG330

Ametherm

ICL 4 OHM 20% 14A 22.86MM

1863

MS22 50004-B

MS22 50004-B

Ametherm

ICL 50 OHM 25% 4A 23MM

0

SG311

SG311

Ametherm

ICL 5 OHM 15% 7A 15.24MM

0

SG307

SG307

Ametherm

ICL 2.5 OHM 15% 15A 22.86MM

0

MM35 1R550

MM35 1R550

Ametherm

ICL 1.5 OHM 25% 50A 68MM

4

SL15 5R007-B

SL15 5R007-B

Ametherm

ICL 5 OHM 20% 7A 16MM

0

SL05 30001-A

SL05 30001-A

Ametherm

ICL 30 OHM 5% 250MA 6MM

0

MS32 7R015

MS32 7R015

Ametherm

ICL 7 OHM 20% 15A 31MM

0

SL32 0R230

SL32 0R230

Ametherm

ICL 300 MOHM 25% 30A 31MM

1373

MS35 0R550

MS35 0R550

Ametherm

ICL 500 MOHM 50A 35MM

224

MS22 12103

MS22 12103

Ametherm

ICL 120 OHM 25% 3A 23MM

0

SL22 2R515

SL22 2R515

Ametherm

ICL 2.5 OHM 20% 15A 22MM

15356

SL32 1R030

SL32 1R030

Ametherm

ICL 1 OHM 20% 30A 31MM

508

SL10 50001-B

SL10 50001-B

Ametherm

ICL 50 OHM 25% 1.1A 10MM

0

SL10 25002

SL10 25002

Ametherm

ICL 25 OHM 25% 2A 10MM

198

SL15 12102-B

SL15 12102-B

Ametherm

ICL 120 OHM 25% 2A 15MM

0

SL15 10006

SL15 10006

Ametherm

ICL 10 OHM 20% 6A 16MM

4841

SL15 2R509

SL15 2R509

Ametherm

ICL 2.5 OHM 20% 9A 16MM

0

SL32 1R030-B

SL32 1R030-B

Ametherm

ICL 1 OHM 20% 30A 31MM

618

SL22 60003

SL22 60003

Ametherm

ICL 60 OHM 25% 3A 22MM

0

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.