Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
MM35 1R050

MM35 1R050

Ametherm

ICL 1 OHM 25% 50A 68MM

0

SL12 1R010

SL12 1R010

Ametherm

ICL 1 OHM 20% 10A 13MM

0

SL08 12101-A

SL08 12101-A

Ametherm

ICL 120 OHM 20% 1A 8MM

0

MM35 0R280

MM35 0R280

Ametherm

ICL 200 MOHM 25% 80A 68MM

12

SG44

SG44

Ametherm

ICL 5 OHM 15% 7A 15.24MM

0

MS22 10008

MS22 10008

Ametherm

ICL 10 OHM 25% 8A 23MM

14195

SL18 47003-A

SL18 47003-A

Ametherm

ICL 47 OHM 20% 3A 19MM

0

SL22 10009-B

SL22 10009-B

Ametherm

ICL 10 OHM 20% 9A 22MM

0

SL22 5R012-B

SL22 5R012-B

Ametherm

ICL 5 OHM 15% 12A 22MM

283

MS32 2R025-B

MS32 2R025-B

Ametherm

ICL 2 OHM 25% 25A 31MM

0

SL12 10004-B

SL12 10004-B

Ametherm

ICL 10 OHM 20% 4A 13MM

0

SL22 1R020-A

SL22 1R020-A

Ametherm

ICL 1 OHM 20% 20A 22MM

0

SL22 2R515-B

SL22 2R515-B

Ametherm

ICL 2.5 OHM 20% 15A 22MM

1086

SL15 22102-B

SL15 22102-B

Ametherm

ICL 220 OHM 25% 2A 16MM

0

SL10 10003-A

SL10 10003-A

Ametherm

ICL 10 OHM 20% 3A 10MM

0

SG260

SG260

Ametherm

ICL 500 MOHM 20% 30A 31.75MM

913

SL10 25002-A

SL10 25002-A

Ametherm

ICL 25 OHM 25% 2A 10MM

503

SG160

SG160

Ametherm

ICL 2.5 OHM 15% 15A 22.86MM

5559

SL15 40004

SL15 40004

Ametherm

ICL 40 OHM 20% 4A 16MM

227

SG420

SG420

Ametherm

ICL 2 OHM 25% 23A 31.75MM

2628

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.