Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
SL15 40004-A

SL15 40004-A

Ametherm

ICL 40 OHM 20% 4A 16MM

0

SL32 2R023

SL32 2R023

Ametherm

ICL 2 OHM 20% 23A 31MM

1166

SL22 0R712-A

SL22 0R712-A

Ametherm

ICL 700 MOHM 25% 12A 22MM

0

SL05 4R003

SL05 4R003

Ametherm

ICL 4 OHM 20% 3A 6MM

0

SL22 5R012-A

SL22 5R012-A

Ametherm

ICL 5 OHM 20% 12A 22MM

0

MS32 15012-B

MS32 15012-B

Ametherm

ICL 15 OHM 25% 12A 31MM

0

SL15 2R507-B

SL15 2R507-B

Ametherm

ICL 2.5 OHM 20% 7A 16MM

0

SL12 12103

SL12 12103

Ametherm

ICL 120 OHM 20% 3A 12MM

971

SL15 12102

SL15 12102

Ametherm

ICL 120 OHM 25% 2A 15MM

710

SL12 5R004

SL12 5R004

Ametherm

ICL 5 OHM 20% 4A 13MM

1045

SG220

SG220

Ametherm

ICL 10 OHM 15% 3A 11.43MM

2375

SL10 5R004-A

SL10 5R004-A

Ametherm

ICL 5 OHM 20% 4A 10MM

0

SL10 2R005-B

SL10 2R005-B

Ametherm

ICL 2 OHM 25% 5A 10MM

0

SG26

SG26

Ametherm

ICL 5 OHM 15% 12A 22.86MM

0

SL22 20005

SL22 20005

Ametherm

ICL 20 OHM 20% 5A 22MM

0

SL22 10008

SL22 10008

Ametherm

ICL 10 OHM 20% 8A 22MM

1629

SL10 50002-A

SL10 50002-A

Ametherm

ICL 50 OHM 25% 2A 10MM

0

SL12 25002-B

SL12 25002-B

Ametherm

ICL 25 OHM 20% 2A 13MM

0

SL15 22101-A

SL15 22101-A

Ametherm

ICL 220 OHM 25% 1A 16MM

88

SL15 22102-A

SL15 22102-A

Ametherm

ICL 220 OHM 25% 2A 16MM

3911

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.