Fuses

Image Part Number Description / PDF Quantity Rfq
74-3FG100MA

74-3FG100MA

NTE Electronics, Inc.

FUSE GLASS 100MA 250VAC CART

166

74-AF5A

74-AF5A

NTE Electronics, Inc.

FUSE AUTO 5A 32VDC BLADE

842

74-4SGL6A

74-4SGL6A

NTE Electronics, Inc.

FUSE GLASS 6A 125VAC 2AG

224

74-5FCL630MA

74-5FCL630MA

NTE Electronics, Inc.

FUSE CERAMIC 630MA 250VAC 5X20MM

1760

74-6FC750MA

74-6FC750MA

NTE Electronics, Inc.

FUSE CERAMIC 750MA 250VAC 6X30MM

1025

74-6SC750MA

74-6SC750MA

NTE Electronics, Inc.

FUSE CERAMIC 750MA 250VAC 6X30MM

696

74-LAF20A

74-LAF20A

NTE Electronics, Inc.

FUSE AUTO 20A 32VDC BLADE

851

74-6SG600MA

74-6SG600MA

NTE Electronics, Inc.

FUSE GLASS 600MA 250VAC 6X30MM

1761

74-10FC20A

74-10FC20A

NTE Electronics, Inc.

FUSE CERAMIC 20A 1KVAC 1KVDC 5AG

90

74-5FG1A

74-5FG1A

NTE Electronics, Inc.

FUSE GLASS 1A 250VAC 5X20MM

5577

74-6SC20A

74-6SC20A

NTE Electronics, Inc.

FUSE CERAMIC 20A 250VAC 6X30MM

0

74-MAF15A

74-MAF15A

NTE Electronics, Inc.

FUSE AUTO 15A 32VDC BLADE MINI

1988

74-MF750MA

74-MF750MA

NTE Electronics, Inc.

FUSE BOARD MT 750MA 125VAC AXIAL

652

74-5SG200MA

74-5SG200MA

NTE Electronics, Inc.

FUSE GLASS 200MA 250VAC 5X20MM

1744

74-MS2A

74-MS2A

NTE Electronics, Inc.

FUSE BOARD MOUNT 2A 125VAC AXIAL

1432

74-LMAF10A

74-LMAF10A

NTE Electronics, Inc.

FUSE AUTO 10A 32VDC BLADE MINI

655

74-10FC12A

74-10FC12A

NTE Electronics, Inc.

FUSE CERAMIC 12A 1KVAC 1KVDC 5AG

54

74-MF5A

74-MF5A

NTE Electronics, Inc.

FUSE BOARD MOUNT 5A 125VAC AXIAL

370

74-4FGL4A

74-4FGL4A

NTE Electronics, Inc.

FUSE GLASS 4A 250VAC 2AG

1360

74-6SC10A

74-6SC10A

NTE Electronics, Inc.

FUSE CERAMIC 10A 250VAC 6X30MM

614

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top