Fuses

Image Part Number Description / PDF Quantity Rfq
74-5FCL200MA

74-5FCL200MA

NTE Electronics, Inc.

FUSE CERAMIC 200MA 250VAC 5X20MM

557

74-5SCL6.3A

74-5SCL6.3A

NTE Electronics, Inc.

FUSE CERAMIC 6.3A 250VAC 5X20MM

58

74-5FCL100MA

74-5FCL100MA

NTE Electronics, Inc.

FUSE CERAMIC 100MA 250VAC 5X20MM

537

74-4SGL350MA

74-4SGL350MA

NTE Electronics, Inc.

FUSE GLASS 350MA 250VAC 2AG

596

74-6FG250MA

74-6FG250MA

NTE Electronics, Inc.

FUSE GLASS 250MA 250VAC 6X30MM

2247

74-5FCL125MA

74-5FCL125MA

NTE Electronics, Inc.

FUSE CERAMIC 125MA 250VAC 5X20MM

544

74-6SG400MA

74-6SG400MA

NTE Electronics, Inc.

FUSE GLASS 400MA 250VAC 6X30MM

772

74-5FG250MA

74-5FG250MA

NTE Electronics, Inc.

FUSE GLASS 250MA 250VAC 5X20MM

3655

74-5FCL500MA

74-5FCL500MA

NTE Electronics, Inc.

FUSE CERAMIC 500MA 250VAC 5X20MM

379

74-6FC375MA

74-6FC375MA

NTE Electronics, Inc.

FUSE CERAMIC 375MA 250VAC 6X30MM

533

74-LMAF25A

74-LMAF25A

NTE Electronics, Inc.

FUSE AUTO 25A 32VDC BLADE MINI

1288

74-4SGL375MA

74-4SGL375MA

NTE Electronics, Inc.

FUSE GLASS 375MA 250VAC 2AG

628

74-6FG10A

74-6FG10A

NTE Electronics, Inc.

FUSE GLASS 10A 250VAC 6X30MM

3886

74-5SG2A

74-5SG2A

NTE Electronics, Inc.

FUSE GLASS 2A 250VAC 5X20MM

2730

74-AF20A

74-AF20A

NTE Electronics, Inc.

FUSE AUTO 20A 32VDC BLADE

1022

74-4FG3A

74-4FG3A

NTE Electronics, Inc.

FUSE GLASS 3A 250VAC 2AG

677

74-5FCL800MA

74-5FCL800MA

NTE Electronics, Inc.

FUSE CERAMIC 800MA 250VAC 5X20MM

593

74-6FG500MA

74-6FG500MA

NTE Electronics, Inc.

FUSE GLASS 500MA 250VAC 6X30MM

2633

74-5FG15A

74-5FG15A

NTE Electronics, Inc.

FUSE GLASS 15A 250VAC 5X20MM

2384

74-4SGL4A

74-4SGL4A

NTE Electronics, Inc.

FUSE GLASS 4A 125VAC 2AG

981

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures