Fuses

Image Part Number Description / PDF Quantity Rfq
74-5FCL16A

74-5FCL16A

NTE Electronics, Inc.

FUSE CERAMIC 16A 250VAC 5X20MM

231

74-6SG20A

74-6SG20A

NTE Electronics, Inc.

FUSE GLASS 20A 250VAC 6X30MM

3717

74-6SG250MA

74-6SG250MA

NTE Electronics, Inc.

FUSE GLASS 250MA 250VAC 6X30MM

1520

74-4SGL1A

74-4SGL1A

NTE Electronics, Inc.

FUSE GLASS 1A 250VAC 2AG

199

74-6FC20A

74-6FC20A

NTE Electronics, Inc.

FUSE CERAMIC 20A 250VAC 6X30MM

4729

74-4SGL3A

74-4SGL3A

NTE Electronics, Inc.

FUSE GLASS 3A 250VAC 2AG

813

74-MF1A

74-MF1A

NTE Electronics, Inc.

FUSE BOARD MOUNT 1A 125VAC AXIAL

954

74-5SC200MA

74-5SC200MA

NTE Electronics, Inc.

FUSE CERAMIC 200MA 250VAC 5X20MM

1483

74-5SC12.5A

74-5SC12.5A

NTE Electronics, Inc.

FUSE CERAMIC 12.5A 250VAC 5X20MM

616

74-5SCL400MA

74-5SCL400MA

NTE Electronics, Inc.

FUSE CERAMIC 400MA 250VAC 5X20MM

648

74-6SG150MA

74-6SG150MA

NTE Electronics, Inc.

FUSE GLASS 150MA 250VAC 6X30MM

471

74-4FG375MA

74-4FG375MA

NTE Electronics, Inc.

FUSE GLASS 375MA 250VAC 2AG

1355

74-4FGL5A

74-4FGL5A

NTE Electronics, Inc.

FUSE GLASS 5A 250VAC 2AG

701

74-6SG15A

74-6SG15A

NTE Electronics, Inc.

FUSE GLASS 15A 250VAC 6X30MM

479

74-5FG500MA

74-5FG500MA

NTE Electronics, Inc.

FUSE GLASS 500MA 250VAC 5X20MM

4657

74-5FC4A

74-5FC4A

NTE Electronics, Inc.

FUSE CERAMIC 4A 250VAC 5X20MM

493

74-MIC2-25A

74-MIC2-25A

NTE Electronics, Inc.

AUTO FUSE 25A MICRO-2

620

74-4SG2.5A

74-4SG2.5A

NTE Electronics, Inc.

FUSE GLASS 2.5A 250VAC 2AG

978

74-5FCL2.5A

74-5FCL2.5A

NTE Electronics, Inc.

FUSE CERAMIC 2.5A 250VAC 5X20MM

160

74-5FC3.15A

74-5FC3.15A

NTE Electronics, Inc.

FUSE CERAMIC 3.15A 250VAC 5X20MM

1604

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top