Fuses

Image Part Number Description / PDF Quantity Rfq
74-6SG3.5A

74-6SG3.5A

NTE Electronics, Inc.

FUSE GLASS 3.5A 250VAC 6X30MM

822

74-6SG100MA

74-6SG100MA

NTE Electronics, Inc.

FUSE GLASS 100MA 250VAC 6X30MM

784

74-6SC600MA

74-6SC600MA

NTE Electronics, Inc.

FUSE CERAMIC 600MA 250VAC 6X30MM

612

74-5FC125MA

74-5FC125MA

NTE Electronics, Inc.

FUSE CERAMIC 125MA 250VAC 5X20MM

326

74-6SC700MA

74-6SC700MA

NTE Electronics, Inc.

FUSE CERAMIC 700MA 250VAC 6X30MM

182

74-10FC15A

74-10FC15A

NTE Electronics, Inc.

FUSE CERAMIC 15A 1KVAC 1KVDC 5AG

13

74-5SG5A

74-5SG5A

NTE Electronics, Inc.

FUSE GLASS 5A 250VAC 5X20MM

3105

74-4FGL8A

74-4FGL8A

NTE Electronics, Inc.

FUSE GLASS 8A 125VAC 2AG

388

74-5SC12A

74-5SC12A

NTE Electronics, Inc.

FUSE CERAMIC 12A 250VAC 5X20MM

1464

74-5FCL250MA

74-5FCL250MA

NTE Electronics, Inc.

FUSE CERAMIC 250MA 250VAC 5X20MM

491

74-6SG375MA

74-6SG375MA

NTE Electronics, Inc.

FUSE GLASS 375MA 250VAC 6X30MM

286

74-3FG3A

74-3FG3A

NTE Electronics, Inc.

FUSE GLASS 3A 250VAC CARTRIDGE

334

74-3SG1.25A

74-3SG1.25A

NTE Electronics, Inc.

FUSE GLASS 1.25A 250VAC CART

144

74-LPM-4A

74-LPM-4A

NTE Electronics, Inc.

AUTO FUSE 4A LOW PROFILE

612

74-6SC2.5A

74-6SC2.5A

NTE Electronics, Inc.

FUSE CERAMIC 2.5A 250VAC 6X30MM

2147

74-MF10A

74-MF10A

NTE Electronics, Inc.

FUSE BOARD MNT 10A 125VAC AXIAL

938

74-4FGL6A

74-4FGL6A

NTE Electronics, Inc.

FUSE GLASS 6A 125VAC 2AG

444

74-6SC3A

74-6SC3A

NTE Electronics, Inc.

FUSE CERAMIC 3A 250VAC 6X30MM

685

74-10FC2A

74-10FC2A

NTE Electronics, Inc.

FUSE CERAMIC 2A 1KVAC 1KVDC 5AG

11

74-5FC400MA

74-5FC400MA

NTE Electronics, Inc.

FUSE CERAMIC 400MA 250VAC 5X20MM

1022

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top