Fuses

Image Part Number Description / PDF Quantity Rfq
0697H5000-01

0697H5000-01

Bel Fuse, Inc.

FUSE BRD MNT 5A 350VAC 72VDC

383

3AB 4-R

3AB 4-R

Bel Fuse, Inc.

FUSE CERAMIC 4A 250VAC 3AB 3AG

734

0251007.MRT1L

0251007.MRT1L

Wickmann / Littelfuse

FUSE BRD MNT 7A 125VAC/VDC AXIAL

1273

MRT 2-BULK

MRT 2-BULK

Bel Fuse, Inc.

FUSE BOARD MOUNT 2A 250VAC RAD

0

SF-0603HI150M-2

SF-0603HI150M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 1.5A 32VDC 0603

0

0464004.DR

0464004.DR

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 250VAC 2SMD

3958

AMG-200

AMG-200

Eaton

FUSE AUTO 200A 32VDC AUTO LINK

0

3061347

3061347

Phoenix Contact

FUSE CERAMIC 12A 1000VDC 5AG

29

0216001.MRET1P

0216001.MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 1A 250VAC 5X20MM

0

0315.010MXP

0315.010MXP

Wickmann / Littelfuse

FUSE GLASS 10MA 250VAC 3AB 3AG

0

BK/ABC-V-1/4-R

BK/ABC-V-1/4-R

PowerStor (Eaton)

FUSE CERAMIC 250MA 250VAC 125VDC

0

SF-1206S500-2

SF-1206S500-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 5A 32VDC 1206

0

0154001.DRTL

0154001.DRTL

Wickmann / Littelfuse

FUSE BRD MNT 1A 125VAC/VDC 2SMD

3078

TFLS-50A

TFLS-50A

OptiFuse

AUTO LINK FUSE, MINI FEMALE-50A

833

0327015.YX2S

0327015.YX2S

Wickmann / Littelfuse

FUSE MICRO2 BLADE 32V SILVER 15A

2912

0216016.MRET1P

0216016.MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 16A 250VAC 5X20MM

0

BK/AGX-4

BK/AGX-4

PowerStor (Eaton)

FUSE GLASS 4A 250VAC 8AG

115

0218005.HXP

0218005.HXP

Wickmann / Littelfuse

FUSE GLASS 5A 250VAC 5X20MM

7444

BK/GDB-63MA

BK/GDB-63MA

PowerStor (Eaton)

FUSE GLASS 63MA 250VAC 5X20MM

0

0876.160MXEP

0876.160MXEP

Wickmann / Littelfuse

FUSE CERAMIC 160MA 250VAC AXIAL

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top