Fuses

Image Part Number Description / PDF Quantity Rfq
0230.250DRT3P

0230.250DRT3P

Wickmann / Littelfuse

FUSE GLASS 250MA 250VAC 125VDC

0

0034.3117.PT

0034.3117.PT

Schurter

FUSE GLASS 1A 250VAC 5X20MM

1363

0235004.VXP

0235004.VXP

Wickmann / Littelfuse

FUSE GLASS 4A 125VAC 5X20MM

0

0154.500DRT

0154.500DRT

Wickmann / Littelfuse

FUSE BOARD MNT 500MA 125VAC/VDC

7061

0034.7213

0034.7213

Schurter

FUSE BOARD MNT 630MA 250VAC RAD

100

F0805B1R00FSTR

F0805B1R00FSTR

Elco (AVX)

FUSE BOARD MOUNT 1A 63VDC 0805

24053000

BK/GMD-1.2-R

BK/GMD-1.2-R

PowerStor (Eaton)

FUSE GLASS 1.2A 250VAC 5X20MM

971

0224001.DRT2P

0224001.DRT2P

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 125VDC 2AG

0

AGC-12-R

AGC-12-R

PowerStor (Eaton)

FUSE GLASS 12A 32VAC 3AB 3AG

0

0034.6607

0034.6607

Schurter

FUSE BRD MNT 160MA 250VAC 125VDC

980

7010.6440.13

7010.6440.13

Schurter

SUB-MINIATURE FUSE-LINKS TYPE 17

129

0498080.MXT-CN

0498080.MXT-CN

Wickmann / Littelfuse

FUSE - MIDI 32VDC W/CLEAR HOUSIN

0

AGC-3/8-R

AGC-3/8-R

PowerStor (Eaton)

FUSE GLASS 375MA 250VAC 3AB 3AG

0

0322020.MXP

0322020.MXP

Wickmann / Littelfuse

FUSE CERAMIC 20A 65VAC/VDC 3AB

0

087402.5MXEP

087402.5MXEP

Wickmann / Littelfuse

FUSE CERAMIC 2.5A 250VAC AXIAL

0

0233006.MXF11P

0233006.MXF11P

Wickmann / Littelfuse

FUSE GLASS 6A 125VAC 5X20MM

0

FSC-750MA

FSC-750MA

OptiFuse

GLASS - 5X20MM (UL), FAST 750MA

7978

0230006.HXSP

0230006.HXSP

Wickmann / Littelfuse

FUSE GLASS 6A 125VAC/VDC AXIAL

0

0459001.UR

0459001.UR

Wickmann / Littelfuse

FUSE BRD MNT 1A 125VAC/VDC 2SMD

3559

0230.800MXP

0230.800MXP

Wickmann / Littelfuse

FUSE GLASS 800MA 250VAC 125VDC

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top