Fuses

Image Part Number Description / PDF Quantity Rfq
0471004.NRT1L

0471004.NRT1L

Wickmann / Littelfuse

FUSE BRD MNT 4A 125VAC/VDC AXIAL

0

5HT 3.15-R

5HT 3.15-R

Bel Fuse, Inc.

FUSE CERAMIC 3.15A 250VAC 5X20MM

319

0225010.VXUP

0225010.VXUP

Wickmann / Littelfuse

FUSE GLASS 10A 125VAC 2AG

0

0913702

0913702

Phoenix Contact

FUSE AUTOMOTIVE 7.5A BLADE

0

023002.5MXP

023002.5MXP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 125VDC

0

0314010.MXANP

0314010.MXANP

Wickmann / Littelfuse

FUSE CERM 10A 250VAC 125VDC 3AB

776

BK/GMW-3/10

BK/GMW-3/10

PowerStor (Eaton)

FUSE BOARD MNT 300MA 125VAC RAD

100

0208010.MXEP

0208010.MXEP

Wickmann / Littelfuse

FUSE GLASS 10A 350VAC 2AG

860

021506.3MXF155SPP

021506.3MXF155SPP

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC RADIAL

0

3-103-116

3-103-116

Schurter

MGA-A FUSE 2A SOLID STATE THIN F

0

TR2/1025FA1.5-R

TR2/1025FA1.5-R

PowerStor (Eaton)

FUSE BRD MNT 1.5A 250VAC 125VDC

0

TSA-1.5A

TSA-1.5A

OptiFuse

GLASS FUSE-6.3X32MM, SLOW 1.5A

2226

0875005.MXEP

0875005.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 5A 250VAC AXIAL

177

38216300410

38216300410

Wickmann / Littelfuse

FUSE BOARD MOUNT 6.3A 250VAC RAD

0

0202005.H

0202005.H

Wickmann / Littelfuse

FUSE BOARD MOUNT 5A 250VAC 2DIP

600

0686F3500-01

0686F3500-01

Bel Fuse, Inc.

FUSE BRD MNT 3.5A 63VDC 0603

5504

QF1206F1A75T

QF1206F1A75T

AEM

AUTOMOTIVE FUSE, 1.75A, 63VDC

3000

5TT 5-R

5TT 5-R

Bel Fuse, Inc.

FUSE GLASS 5A 125VAC 5X20MM

766

74-4FG4A

74-4FG4A

NTE Electronics, Inc.

FUSE GLASS 4A 250VAC 2AG

388

TSA-100MA

TSA-100MA

OptiFuse

GLASS FUSE-6.3X32MM, SLOW 100MA

1280

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top