Fuses

Image Part Number Description / PDF Quantity Rfq
5ST 8-R

5ST 8-R

Bel Fuse, Inc.

FUSE GLASS 8A 250VAC 5X20MM

4423

TR2-S505H-V-2-R

TR2-S505H-V-2-R

PowerStor (Eaton)

FUSE CERM 2A 600VAC 400VDC 5X20

1346

0034.5624.11

0034.5624.11

Schurter

FUSE GLASS 5A 250VAC 5X20MM

263

SF-0603HI100M-2

SF-0603HI100M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 1A 32VDC 0603

0

TFLB-140A

TFLB-140A

OptiFuse

LINK FUSE 13/16" AXIAL MALE-140A

965

BK/S501-6.3-R

BK/S501-6.3-R

PowerStor (Eaton)

FUSE CERAMIC 6.3A 250VAC 5X20MM

717

0239.700VXP

0239.700VXP

Wickmann / Littelfuse

FUSE GLASS 700MA 250VAC 5X20MM

0

BK-S506-5-R

BK-S506-5-R

TubeDepot

5X20MM GLASS FUSE SLOWBLOW 5A

174

35608000029

35608000029

Wickmann / Littelfuse

FUSE CERM 800MA 440VAC 3AB 3AG

281

74-5SG4A

74-5SG4A

NTE Electronics, Inc.

FUSE GLASS 4A 250VAC 5X20MM

5644

0874.200MXEP

0874.200MXEP

Wickmann / Littelfuse

FUSE CERAMIC 200MA 250VAC AXIAL

0

02191.25MXAP

02191.25MXAP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 5X20MM

0

0679L0750-01

0679L0750-01

Bel Fuse, Inc.

FUSE BRD MNT 750MA 125VAC/VDC

0

0451.630NRL

0451.630NRL

Wickmann / Littelfuse

FUSE BOARD MNT 630MA 125VAC/VDC

0

TR2/C518-3-R

TR2/C518-3-R

PowerStor (Eaton)

FUSE GLASS 3A 250VAC 2AG

0

BK/C515-1.5-R

BK/C515-1.5-R

PowerStor (Eaton)

FUSE GLASS 1.5A 250VAC 2AG

129

BK/GDC-80MA

BK/GDC-80MA

PowerStor (Eaton)

FUSE GLASS 80MA 250VAC 5X20MM

0

SF-0603SP400M-2

SF-0603SP400M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 4A 32VDC 0603

410

0697W2000-02

0697W2000-02

Bel Fuse, Inc.

FUSE 2A 350V RADIAL

2826

BK/PCC-2-1/2-R

BK/PCC-2-1/2-R

PowerStor (Eaton)

FUSE BRD MNT 2.5A 250VAC 450VDC

3

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top