Fuses

Image Part Number Description / PDF Quantity Rfq
3404.2422.22

3404.2422.22

Schurter

FUSE BOARD MNT 4A 277VAC 250VDC

461000

3SB 10-R

3SB 10-R

Bel Fuse, Inc.

FUSE GLASS 10A 125VAC 3AB 3AG

2895

SR-5-800MA-AP

SR-5-800MA-AP

PowerStor (Eaton)

FUSE BOARD MNT 800MA 250VAC RAD

998

FCD-5A

FCD-5A

OptiFuse

CERAMIC - 5X20MM (IEC), FAST 5A

8000

0203.250H

0203.250H

Wickmann / Littelfuse

FUSE BOARD MNT 250MA 250VAC 2DIP

0

BK/PCB-1/2-R

BK/PCB-1/2-R

PowerStor (Eaton)

FUSE BRD MNT 500MA 250VAC 450VDC

3252

74-5FCL400MA

74-5FCL400MA

NTE Electronics, Inc.

FUSE CERAMIC 400MA 250VAC 5X20MM

572

0698Q2000-01

0698Q2000-01

Bel Fuse, Inc.

FUSE 2A 350V RADIAL

867

0034.5138

0034.5138

Schurter

FUSE GLASS 4A 250VAC 3AB 3AG

66

QF0603GA500T

QF0603GA500T

AEM

AUTOMOTIVE FUSE, 0.5A, 65VDC

3000

FSA-315MA

FSA-315MA

OptiFuse

GLASS FUSE-6.3X32MM, FAST 315MA

765

BK/C518S-500-R

BK/C518S-500-R

PowerStor (Eaton)

FUSE GLASS 500MA 250VAC 2AG

0

SS-5F-1A-AP

SS-5F-1A-AP

PowerStor (Eaton)

FUSE BOARD MNT 1A 250VAC RADIAL

966

BK/MDL-V-1-8/10

BK/MDL-V-1-8/10

PowerStor (Eaton)

FUSE GLASS 1.8A 250VAC 3AB 3AG

0

0ADAC2500-BE

0ADAC2500-BE

Bel Fuse, Inc.

FUSE CERM 2.5A 600VAC/VDC

152

20105000021

20105000021

Wickmann / Littelfuse

FUSE GLASS 500MA 250VAC 5X20MM

0

0451.800NRL

0451.800NRL

Wickmann / Littelfuse

FUSE BOARD MNT 800MA 125VAC/VDC

0

C308F125MA-TR

C308F125MA-TR

PowerStor (Eaton)

3X8.4FA, CERAMIC FUSE, 125MA, TR

0

BK/S501-125-R

BK/S501-125-R

PowerStor (Eaton)

FUSE CERAMIC 125MA 250VAC 5X20MM

135

0263.375HAT1L

0263.375HAT1L

Wickmann / Littelfuse

FUSE BRD MNT 375MA 250VAC AXIAL

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top