Fuses

Image Part Number Description / PDF Quantity Rfq
37216300001

37216300001

Wickmann / Littelfuse

FUSE BOARD MOUNT 6.3A 250VAC RAD

2997

0451.500NRL

0451.500NRL

Wickmann / Littelfuse

FUSE BOARD MNT 500MA 125VAC/VDC

2084

045401.5MR

045401.5MR

Wickmann / Littelfuse

FUSE BRD MNT 1.5A 125VAC/VDC SMD

322227000

BK/S501-V-160-R

BK/S501-V-160-R

PowerStor (Eaton)

FUSE CERAMIC 160MA 250VAC 5X20MM

0

5MF 700-R

5MF 700-R

Bel Fuse, Inc.

FUSE GLASS 700MA 250VAC 5X20MM

0

MDL-3/10-R

MDL-3/10-R

PowerStor (Eaton)

FUSE GLASS 300MA 250VAC 3AB 3AG

0

74-5SC8A

74-5SC8A

NTE Electronics, Inc.

FUSE CERAMIC 8A 250VAC 5X20MM

1376

SR-5-1.25A-BK

SR-5-1.25A-BK

PowerStor (Eaton)

FUSE BRD MNT 1.25A 250VAC RADIAL

0

8020.5074.PT

8020.5074.PT

Schurter

FUSE CERAMIC 4A 500VAC 3AB 3AG

438

BK/S500-50-R

BK/S500-50-R

PowerStor (Eaton)

FUSE GLASS 50MA 250VAC 5X20MM

190

0875010.MXEP

0875010.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 10A 250VAC AXIAL

0

0034.6018

0034.6018

Schurter

FUSE BOARD MOUNT 2.5A 250VAC RAD

446

0202004.URG

0202004.URG

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 250VAC 2SMD

1000

0001.1030

0001.1030

Schurter

FUSE GLASS 4A 250VAC 3AB 3AG

190

BK/AGC-V-1/2-R

BK/AGC-V-1/2-R

PowerStor (Eaton)

FUSE GLASS 500MA 250VAC 3AB 3AG

603

ERB-RE1R40V

ERB-RE1R40V

Panasonic

FUSE BOARD MOUNT 1.4A 32VDC 0603

4680

TSA-6A

TSA-6A

OptiFuse

GLASS FUSE - 6.3X32MM, SLOW 6A

3000

3405.0165.24

3405.0165.24

Schurter

UMF 250 FUSE 800MA F SMT

1996

3413.0326.22

3413.0326.22

Schurter

FUSE BRD MNT 7A 32VAC 63VDC 1206

47956

MDA-1-1/4-R

MDA-1-1/4-R

PowerStor (Eaton)

FUSE CERM 1.25A 250VAC 3AB 3AG

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top