Fuses

Image Part Number Description / PDF Quantity Rfq
02163.15MXEP

02163.15MXEP

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 250VAC 5X20MM

0

BK/C515S-4-R

BK/C515S-4-R

PowerStor (Eaton)

FUSE GLASS 4A 125VAC 2AG

0

0263.125HAT1L

0263.125HAT1L

Wickmann / Littelfuse

FUSE BOARD MOUNT 125MA 250VAC

57

MFU1206FF00750P500

MFU1206FF00750P500

Vishay / Beyschlag

FUSE BOARD MNT 750MA 63VDC 1206

0

BK/C520-125-R

BK/C520-125-R

PowerStor (Eaton)

FUSE GLASS 125MA 250VAC 2AG

903

7010.9965.63

7010.9965.63

Schurter

FUSE BOARD MNT 3.15A 125VAC/VDC

932

0202.125HXG

0202.125HXG

Wickmann / Littelfuse

FUSE BOARD MNT 125MA 250VAC 2SMD

200

021506.3HXP

021506.3HXP

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC 5X20MM

1689

0876.630MRET1P

0876.630MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 630MA 250VAC AXIAL

0

020802.5MXEP

020802.5MXEP

Wickmann / Littelfuse

FUSE GLASS 2.5A 350VAC 2AG

0

0ACA-9300-TE

0ACA-9300-TE

Bel Fuse, Inc.

FUSE 30A 72VDC SLOW SMD 2410

0

0230006.VXSP

0230006.VXSP

Wickmann / Littelfuse

FUSE GLASS 6A 125VAC/VDC AXIAL

0

BK/C515S-1.25-R

BK/C515S-1.25-R

PowerStor (Eaton)

FUSE GLASS 1.25A 250VAC 2AG

0

74-AF10A

74-AF10A

NTE Electronics, Inc.

FUSE AUTO 10A 32VDC BLADE

1990

BK/S505-2-R

BK/S505-2-R

PowerStor (Eaton)

FUSE CERAMIC 2A 250VAC 5X20MM

4287

0686F8000-01

0686F8000-01

Bel Fuse, Inc.

FUSE BRD MNT 8A 32VAC 63VDC 0603

150

0501010.WRS

0501010.WRS

Wickmann / Littelfuse

FUSE BOARD MOUNT 10A 32VDC 1206

2664

MGGA-200A

MGGA-200A

OptiFuse

LIMITER FUSE, TIME DELAY, 200A

145

SST 5-5K

SST 5-5K

Bel Fuse, Inc.

FUSE BRD MNT 5A 125VAC/VDC 2SMD

0

0230.800MXSP

0230.800MXSP

Wickmann / Littelfuse

FUSE GLASS 800MA 250VAC 125VDC

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures