Fuses

Image Part Number Description / PDF Quantity Rfq
7010.9830.63

7010.9830.63

Schurter

FUSE CERAMIC 2A 125VAC/VDC

217

7010.6400.13

7010.6400.13

Schurter

FUSE BRD MNT 3A 125VAC/VDC AXIAL

215

02853.15MXRP

02853.15MXRP

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 250VAC 5X20MM

0

80416300440

80416300440

Wickmann / Littelfuse

FUSE BOARD MOUNT 6.3A 250VAC RAD

0

BK/S506-V-125-R

BK/S506-V-125-R

PowerStor (Eaton)

FUSE GLASS 125MA 250VAC 5X20MM

0

0324020.MX280P

0324020.MX280P

Wickmann / Littelfuse

FUSE CERM 20A 280VAC 125VDC 3AB

0

023302.5MXBP

023302.5MXBP

Wickmann / Littelfuse

FUSE GLASS 2.5A 125VAC 5X20MM

0

37203150001

37203150001

Wickmann / Littelfuse

FUSE BOARD MNT 315MA 250VAC RAD

1579

023306.3MXBP

023306.3MXBP

Wickmann / Littelfuse

FUSE GLASS 6.3A 125VAC 5X20MM

0

SF-0603SP200M-2

SF-0603SP200M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 2A 32VDC 0603

2447

FC-5432-15A-C3-C

FC-5432-15A-C3-C

Delta Electronics

SMD FUSE RATED CURRENT 15A/35VDC

0

0498060.MXT-CN

0498060.MXT-CN

Wickmann / Littelfuse

FUSE - MIDI 32VDC W/CLEAR HOUSIN

0

02163.15MXBP

02163.15MXBP

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 250VAC 5X20MM

0

045101.6NRL

045101.6NRL

Wickmann / Littelfuse

FUSE BRD MNT 1.6A 125VAC/VDC SMD

0

0034.3130

0034.3130

Schurter

FUSE GLASS 20A 250VAC 5X20MM

35791000

FSC-80MA

FSC-80MA

OptiFuse

GLASS - 5X20MM (UL), FAST 80MA

824

SF-1206S150W-2

SF-1206S150W-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 1.5A 65VDC 1206

3338

0034.5036

0034.5036

Schurter

FUSE GLASS 200MA 250VAC 5X20MM

1195

3402.0048.24

3402.0048.24

Schurter

FUSE BRD MNT 3.15A 63VAC/VDC SMD

0

ABC-12-R

ABC-12-R

PowerStor (Eaton)

FUSE CERM 12A 250VAC 125VDC 3AB

605

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top