Fuses

Image Part Number Description / PDF Quantity Rfq
0678D0500-02

0678D0500-02

Bel Fuse, Inc.

FUSE SMT 3912 FAST 250V 500MA

3089

02153.15MXF5P

02153.15MXF5P

Wickmann / Littelfuse

FUSE CERAMIC 3.15A 250VAC 5X20MM

0

74-MIC2-15A

74-MIC2-15A

NTE Electronics, Inc.

AUTO FUSE 15A, MICRO-2

352

BK/GDA-125MA

BK/GDA-125MA

PowerStor (Eaton)

FUSE CERAMIC 125MA 250VAC 5X20MM

0

5ST 200-R

5ST 200-R

Bel Fuse, Inc.

FUSE GLASS 200MA 250VAC 5X20MM

1775

37403150410

37403150410

Wickmann / Littelfuse

FUSE BOARD MNT 315MA 250VAC RAD

752

SF-0402F125-2

SF-0402F125-2

J.W. Miller / Bourns

FUSE BOARD MNT 1.25A 32VDC 0402

0

MGGA-100A

MGGA-100A

OptiFuse

LIMITER FUSE, TIME DELAY, 100A

532

03151.25MXP

03151.25MXP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC 3AB 3AG

0

0215005.MXF22P

0215005.MXF22P

Wickmann / Littelfuse

FUSE CERAMIC 5A 250VAC 5X20MM

0

0230003.DRT2SP

0230003.DRT2SP

Wickmann / Littelfuse

FUSE GLASS 3A 250VAC/125VDC AXL

0

0154.375DR

0154.375DR

Wickmann / Littelfuse

FUSE BOARD MNT 375MA 125VAC/VDC

1799

SF-0402F200-2

SF-0402F200-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 2A 32VDC 0402

13715

0477016.MXP

0477016.MXP

Wickmann / Littelfuse

FUSE CERM 16A 500VAC 400VDC 5X20

2831

0218005.MXF11P

0218005.MXF11P

Wickmann / Littelfuse

FUSE GLASS 5A 250VAC 5X20MM

0

0697H1250-01

0697H1250-01

Bel Fuse, Inc.

FUSE BRD MNT 1.25A 350VAC 100VDC

0

0034.7211

0034.7211

Schurter

FUSE BOARD MNT 400MA 250VAC RAD

97

74-4FGL2A

74-4FGL2A

NTE Electronics, Inc.

FUSE GLASS 2A 250VAC 2AG

372

3403.0155.24

3403.0155.24

Schurter

FUSE BRD MNT 80MA 250VAC 125VDC

2930

0266004.V

0266004.V

Wickmann / Littelfuse

FUSE BOARD MNT 4A 125VAC/VDC RAD

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email