Fuses

Image Part Number Description / PDF Quantity Rfq
7010.9519.55

7010.9519.55

Schurter

FUSE BRD MNT 6.3A 125VAC/VDC SMD

0

0451004.NRL

0451004.NRL

Wickmann / Littelfuse

FUSE BRD MNT 4A 125VAC/VDC 2SMD

0

0235.300VXEP

0235.300VXEP

Wickmann / Littelfuse

FUSE GLASS 300MA 250VAC 5X20MM

0

0313.175HXP

0313.175HXP

Wickmann / Littelfuse

FUSE GLASS 175MA 250VAC 3AB 3AG

31

MDL-3-R

MDL-3-R

PowerStor (Eaton)

FUSE GLASS 3A 250VAC 3AB 3AG

0

0441002.WRA

0441002.WRA

Wickmann / Littelfuse

FUSE 2.0A 32V SMD 0603

13716000

BK-S505H-V-3.15-R

BK-S505H-V-3.15-R

PowerStor (Eaton)

FUSE CERAMIC 3.15A 600VAC 400VDC

0

3422.0013.11

3422.0013.11

Schurter

FUSE BRD MNT 2.5A 63VAC/VDC 2SMD

144400

0274.031V

0274.031V

Wickmann / Littelfuse

FUSE BRD MNT 31MA 125VAC/VDC RAD

20

0215012.MXF11P

0215012.MXF11P

Wickmann / Littelfuse

FUSE CERAMIC 12A 250VAC 5X20MM

0

MDL-2-1/2-R

MDL-2-1/2-R

PowerStor (Eaton)

FUSE GLASS 2.5A 250VAC 3AB 3AG

400

FSC-160MA

FSC-160MA

OptiFuse

GLASS - 5X20MM (UL), FAST 160MA

1527

TSA-315MA

TSA-315MA

OptiFuse

GLASS FUSE-6.3X32MM, SLOW 315MA

3670

0435005.KR

0435005.KR

Wickmann / Littelfuse

FUSE BOARD MOUNT 5A 32VDC 0402

8412

C1Q 2.5

C1Q 2.5

Bel Fuse, Inc.

FUSE BOARD MNT 2.5A 125VAC 63VDC

6757

023202.5MXEP

023202.5MXEP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 5X20MM

0

7100.1074.13

7100.1074.13

Schurter

FUSE BOARD MOUNT 8A 250VAC RAD

98

TSA-25A

TSA-25A

OptiFuse

GLASS FUSE-6.3X32MM, SLOW 25A

2453

02200011MRT1P

02200011MRT1P

Wickmann / Littelfuse

FUSE GLASS 350MA 250VAC 2AG

0

0235.100VXP

0235.100VXP

Wickmann / Littelfuse

FUSE GLASS 100MA 250VAC 5X20MM

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top