Fuses

Image Part Number Description / PDF Quantity Rfq
ANM80-1A

ANM80-1A

OptiFuse

FUSE AUTO 1A 80VDC BLADE MINI

0

FPK-7A

FPK-7A

OptiFuse

UL CLASS M FUSE, FAST ACTING 7A

32

SF-1206SP175L-2-A9

SF-1206SP175L-2-A9

J.W. Miller / Bourns

FUSE BOARD MNT 1.75A 63VDC 1206

8514

0154004.DR

0154004.DR

Wickmann / Littelfuse

FUSE BRD MNT 4A 125VAC/VDC 2SMD

519

021701.6MRET1P

021701.6MRET1P

Wickmann / Littelfuse

FUSE GLASS 1.6A 250VAC 5X20MM

0

043502.5KR

043502.5KR

Wickmann / Littelfuse

FUSE BOARD MOUNT 2.5A 32VDC 0402

0

031201.5HXP

031201.5HXP

Wickmann / Littelfuse

FUSE GLASS 1.5A 250VAC 3AB 3AG

1036

BK/ABC-V-1-1/2R

BK/ABC-V-1-1/2R

PowerStor (Eaton)

FUSE CERM 1.5A 250VAC 125VDC 3AB

0

3403.0287.23

3403.0287.23

Schurter

FUSE BRD MNT 20A 250VAC/72VDC

435

3AG 1.6-R

3AG 1.6-R

Bel Fuse, Inc.

FUSE GLASS 1.6A 250VAC 3AB 3AG

884

0324003.HXP

0324003.HXP

Wickmann / Littelfuse

FUSE CERM 3A 250VAC 125VDC 3AB

0

0680L0375-21

0680L0375-21

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 375MA

0

02351.25MXEP

02351.25MXEP

Wickmann / Littelfuse

FUSE GLASS 1.25A 250VAC AXIAL

0

0253010.M

0253010.M

Wickmann / Littelfuse

FUSE BOARD MOUNT 10A 125VAC/VDC

625

74-XAF60A

74-XAF60A

NTE Electronics, Inc.

FUSE AUTO 60A 42VDC BLADE

516

021306.3MRET1P

021306.3MRET1P

Wickmann / Littelfuse

FUSE GLASS 6.3A 250VAC 5X20MM

0

ERB-SD0R50U

ERB-SD0R50U

Panasonic

FUSE BOARD MNT 500MA 24VDC 0402

16236

BK/MDA-V-25-R

BK/MDA-V-25-R

PowerStor (Eaton)

FUSE CERM 25A 250VAC 125VDC 3AB

71

37211600431

37211600431

Wickmann / Littelfuse

FUSE BOARD MOUNT 1.6A 250VAC RAD

8

TFLS-60A

TFLS-60A

OptiFuse

AUTO LINK FUSE, MINI FEMALE-60A

861

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top