Fuses

Image Part Number Description / PDF Quantity Rfq
087501.5MRET1P

087501.5MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 1.5A 250VAC AXIAL

0

0224004.HXUP

0224004.HXUP

Wickmann / Littelfuse

FUSE GLASS 4A 125VAC 2AG

0

0498100.MX1M6-CN

0498100.MX1M6-CN

Wickmann / Littelfuse

FUSE MIDI 32VDC M6 1-HOLE 100A

0

0ADAP0315-RE

0ADAP0315-RE

Bel Fuse, Inc.

FUSE CERM 0.315A 600V AXL

963

FCD-15A

FCD-15A

OptiFuse

CERAMIC - 5X20MM (IEC), FAST 15A

3088

0476005.MR

0476005.MR

Wickmann / Littelfuse

FUSE BOARD MOUNT 250V 5.0A

923

031502.5MXP

031502.5MXP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 3AB 3AG

0

0476007.MRSN

0476007.MRSN

Wickmann / Littelfuse

FUSE BRD MNT 7A 125VAC/VDC 2SMD

0

74-5SG3A

74-5SG3A

NTE Electronics, Inc.

FUSE GLASS 3A 250VAC 5X20MM

2688

BK1/S505-6.3-R

BK1/S505-6.3-R

PowerStor (Eaton)

FUSE CERAMIC 6.3A 250VAC 5X20MM

0

SF-0402S400M-2

SF-0402S400M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 4A 24VDC 0402

9870

02200030MXP

02200030MXP

Wickmann / Littelfuse

FUSE GLASS 375MA 250VAC 125VDC

0

023402.5MXP

023402.5MXP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 5X20MM

3022000

0326.031VXP

0326.031VXP

Wickmann / Littelfuse

FUSE CERAMIC 31MA 250VAC 3AB 3AG

0

0274.500V

0274.500V

Wickmann / Littelfuse

FUSE BOARD MNT 500MA 125VAC/VDC

0

SF-2410SP160W-2

SF-2410SP160W-2

J.W. Miller / Bourns

FUSE BRD 1.6A 250VAC/125DC 2410

1493

MRT 100AMMO

MRT 100AMMO

Bel Fuse, Inc.

FUSE BRD MNT 100MA 250VAC RADIAL

0

0251004.PF001L

0251004.PF001L

Wickmann / Littelfuse

FUSE BRD MNT 4A 125VAC/VDC AXIAL

0

AGC-V-1/32

AGC-V-1/32

PowerStor (Eaton)

FUSE GLASS 31MA 250VAC 3AB 3AG

0

BK1/S500-40-R

BK1/S500-40-R

PowerStor (Eaton)

FUSE 40MA 250V FAST GLASS

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top