Fuses

Image Part Number Description / PDF Quantity Rfq
0325.400MXP

0325.400MXP

Wickmann / Littelfuse

FUSE CERAMIC 400MA 250VAC 125VDC

0

BK/AGX-1-1/2

BK/AGX-1-1/2

PowerStor (Eaton)

FUSE GLASS 1.5A 250VAC 8AG

50

APM-5A

APM-5A

OptiFuse

FUSE AUTO 5A 32VDC BLADE MINI

100498

0325007.MXP

0325007.MXP

Wickmann / Littelfuse

FUSE CERAMIC 7A 250VAC 3AB 3AG

0

0453.375MR

0453.375MR

Wickmann / Littelfuse

FUSE BOARD MNT 375MA 125VAC/VDC

1725

0ADAP0250-RE

0ADAP0250-RE

Bel Fuse, Inc.

FUSE CERM 0.25A 600V AXL

927

SSQC 1.25

SSQC 1.25

Bel Fuse, Inc.

FUSE BOARD MNT 1.25A 125VAC/VDC

0

3410.0021.02

3410.0021.02

Schurter

FUSE BOARD MNT 200MA 125VAC/VDC

0

0154008.DRL

0154008.DRL

Wickmann / Littelfuse

FUSE BRD MNT 8A 125VAC/VDC 2SMD

0

04200001UR

04200001UR

Wickmann / Littelfuse

FUSE BOARD MOUNT 1A 250VAC 2SMD

0

FC-5432-12A-C3-C

FC-5432-12A-C3-C

Delta Electronics

SMD FUSE RATED CURRENT 12A/35VDC

1930

3404.2326.23

3404.2326.23

Schurter

FUSE BOARD MNT 2A 125VAC/VDC SMD

0

F1206B0R25FSTR

F1206B0R25FSTR

Elco (AVX)

FUSE BOARD MNT 250MA 63VDC 1206

6485

BK-GMA-3-15-R

BK-GMA-3-15-R

TubeDepot

5X20MM GLASS FUSE FA 1/2W 3.15A

22

MDL-V-2-1/2-R

MDL-V-2-1/2-R

PowerStor (Eaton)

FUSE GLASS 2.5A 250VAC 3AB 3AG

0

FXG-6A

FXG-6A

OptiFuse

THRU HOLE FUSE 2.7X7.3MM,FAST 6A

0

0325.010MXP

0325.010MXP

Wickmann / Littelfuse

FUSE CERAMIC 10MA 250VAC 3AB 3AG

0

045101.5MRSN

045101.5MRSN

Wickmann / Littelfuse

FUSE BOARD MNT 1.5A 125VAC 2SMD

0

0680L6300-01

0680L6300-01

Bel Fuse, Inc.

FUSE BRICK SMD 2410 SLOW 6.3A

0

021802.5VXP

021802.5VXP

Wickmann / Littelfuse

FUSE GLASS 2.5A 250VAC 5X20MM

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top