Fuses

Image Part Number Description / PDF Quantity Rfq
37213150411

37213150411

Wickmann / Littelfuse

FUSE BRD MNT 3.15A 250VAC RADIAL

625

TCC-7A

TCC-7A

OptiFuse

CERAMIC - 5X20MM (UL), SLOW 7A

217

5ST 400-R

5ST 400-R

Bel Fuse, Inc.

FUSE GLASS 400MA 250VAC 5X20MM

0

0498200.MXM6

0498200.MXM6

Wickmann / Littelfuse

FUSE AUTO 200A 32VDC AUTO LINK

0

0215.315MRET1P

0215.315MRET1P

Wickmann / Littelfuse

FUSE CERAMIC 315MA 250VAC 5X20MM

0

0299025.ZXNV

0299025.ZXNV

Wickmann / Littelfuse

FUSE AUTO 25A 32VDC BLADE

9

74-MAF3A

74-MAF3A

NTE Electronics, Inc.

FUSE AUTO 3A 32VDC BLADE MINI

1627

3413.0121.26

3413.0121.26

Schurter

FUSE BRD MNT 3A 32VAC 63VDC 1206

0

021506.3MXF11P

021506.3MXF11P

Wickmann / Littelfuse

FUSE CERAMIC 6.3A 250VAC 5X20MM

0

0239001.MRET1P

0239001.MRET1P

Wickmann / Littelfuse

FUSE GLASS 1A 250VAC 5X20MM

0

0299035.TXN

0299035.TXN

Wickmann / Littelfuse

FUSE AUTO 35A 32VDC BLADE

25110

30304000001

30304000001

Wickmann / Littelfuse

FUSE BRD MNT 400MA 125VAC 63VDC

0

SF-1206S100-2

SF-1206S100-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 1A 63VDC 1206

2524

80411250000

80411250000

Wickmann / Littelfuse

FUSE BRD MNT 1.25A 250VAC RADIAL

0

BK1/S501-2-R

BK1/S501-2-R

PowerStor (Eaton)

FUSE CERAMIC 2A 250VAC 5X20MM

0

SF-0603S100M-2

SF-0603S100M-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 1A 63VDC 0603

4342

ANR58-UL-35A

ANR58-UL-35A

OptiFuse

FUSE AUTO 35A 250VAC 58VDC BLADE

0

74-MF1.5A

74-MF1.5A

NTE Electronics, Inc.

FUSE BOARD MNT 1.5A 125VAC AXIAL

672

0477.800MXP

0477.800MXP

Wickmann / Littelfuse

FUSE CERAMIC 800MA 500VAC 400VDC

0

3-103-103

3-103-103

Schurter

MGA-A FUSE 750MA SOLID STATE THI

2995

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top