Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
8020.2056

8020.2056

Schurter

FUSE CARTRIDGE 25A 275VAC/1KVDC

92

0090.1020

0090.1020

Schurter

FUSE CARTRIDGE 20A 1KVDC 5AG

0

8020.2061

8020.2061

Schurter

FUSE CARTRIDGE 15A 275VAC/1KVDC

45

0090.0004

0090.0004

Schurter

FUSE CARTRIDGE 4A 1KVDC 5AG

15

8020.2064

8020.2064

Schurter

FUSE CARTRIDGE 40A 275VAC/800VDC

5

0090.1010

0090.1010

Schurter

FUSE CARTRIDGE 10A 1KVDC 5AG

0

0090.0002

0090.0002

Schurter

FUSE CARTRIDGE 2A 1KVDC 5AG

27

0090.1030

0090.1030

Schurter

FUSE CARTRIDGE 30A 1KVDC 5AG

428

0090.0005

0090.0005

Schurter

FUSE CARTRIDGE 5A 1KVDC 5AG

0

0090.1005

0090.1005

Schurter

FUSE CARTRIDGE 5A 1KVDC 5AG

0

8020.2095

8020.2095

Schurter

FUSE CARTRIDGE 50A 275VAC/800VDC

198

0090.0012

0090.0012

Schurter

FUSE CARTRIDGE 12A 1KVDC 5AG

46

0090.0006

0090.0006

Schurter

FUSE CARTRIDGE 6A 1KVDC 5AG

19

0090.0010

0090.0010

Schurter

FUSE CARTRIDGE 10A 1KVDC 5AG

26

8020.2082

8020.2082

Schurter

FUSE CARTRIDGE 20A 275VAC/1KVDC

47

0001.2023

0001.2023

Schurter

FUSE CARTRIDGE 6A 500VAC DT II

39

8020.2066

8020.2066

Schurter

FUSE CARTRIDGE 25A 275VAC/1KVDC

32

8020.2094

8020.2094

Schurter

FUSE CARTRIDGE 40A 275VAC/800VDC

93

8020.2052

8020.2052

Schurter

FUSE CARTRIDGE 20A 275VAC/1KVDC

64

8020.2093

8020.2093

Schurter

FUSE CARTRIDGE 30A 275VAC/1KVDC

48

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email