Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
0090.0008

0090.0008

Schurter

FUSE CARTRIDGE 8A 1KVDC 5AG

86

0034.1103

0034.1103

Schurter

FUSE CARTRIDGE 6A 500VAC GLD II

30

0090.1003

0090.1003

Schurter

FUSE CARTRIDGE 3A 1KVDC 5AG

60

8020.2083

8020.2083

Schurter

FUSE CARTRIDGE 30A 275VAC/1KVDC

62

0090.1001

0090.1001

Schurter

FUSE CARTRIDGE 1A 1KVDC 5AG

44

0090.0030

0090.0030

Schurter

FUSE CARTRIDGE 30A 1KVDC 5AG

1951

0001.2021

0001.2021

Schurter

FUSE CARTRIDGE 2A 500VAC DT II

0

0090.1006

0090.1006

Schurter

FUSE CARTRIDGE 6A 1KVDC 5AG

0

0034.1105

0034.1105

Schurter

FUSE CARTRIDGE 16A 500VAC GLD II

19

0090.1002

0090.1002

Schurter

FUSE CARTRIDGE 2A 1KVDC 5AG

66

7017.5290

7017.5290

Schurter

FUSE CARTRIDGE 6.3A 250VAC 5AG

0

2010.0022

2010.0022

Schurter

FUSE CRTRDGE 3.15A 250VAC 5X20MM

0

2030.0245

2030.0245

Schurter

FUSE BRD MNT 400MA 125VAC/VDC

0

7017.5240

7017.5240

Schurter

FUSE CARTRIDGE 2A 250VAC 5AG

0

7181.4122

7181.4122

Schurter

FUSE CARTRIDGE 2A 500VAC 5AG

0

2030.0244

2030.0244

Schurter

FUSE BRD MNT 315MA 125VAC/VDC

0

2000.0010.11

2000.0010.11

Schurter

FUSE BRD MNT 500MA 600VAC/125VDC

0

2030.0551

2030.0551

Schurter

FUSE BRD MNT 1A 125VAC/VDC RAD

0

2000.0012.24

2000.0012.24

Schurter

FUSE BRD MNT 2A 600VAC/125VDC

0

2030.0250

2030.0250

Schurter

FUSE BRD MNT 800MA 125VAC/VDC

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email