Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
2030.0017

2030.0017

Schurter

FUSE BRD MNT 630MA 125VAC/VDC

0

2000.0011.24

2000.0011.24

Schurter

FUSE BRD MNT 1.25A 600VAC/125VDC

0

2030.0251

2030.0251

Schurter

FUSE BRD MNT 1A 125VAC/VDC RAD

0

2030.0023

2030.0023

Schurter

FUSE BRD MNT 1.6A 125VAC/VDC RAD

0

2030.0016

2030.0016

Schurter

FUSE BRD MNT 500MA 125VAC/VDC

0

2030.0545

2030.0545

Schurter

FUSE BRD MNT 400MA 125VAC/VDC

0

2020.0002

2020.0002

Schurter

FUSE CRTRDGE 630MA 250VAC 5X20MM

0

2030.0013

2030.0013

Schurter

FUSE BRD MNT 250MA 125VAC/VDC

0

2030.0025

2030.0025

Schurter

FUSE BRD MNT 2.5A 125VAC/VDC RAD

0

2030.0554

2030.0554

Schurter

FUSE BRD MNT 2A 125VAC/VDC RAD

0

2000.0010.24

2000.0010.24

Schurter

FUSE BRD MNT 500MA 600VAC/125VDC

0

2020.0008

2020.0008

Schurter

FUSE CRTRDGE 2.5A 250VAC 5X20MM

0

7024.9240

7024.9240

Schurter

FUSE CARTRIDGE 2A 300VAC 5AG

0

2030.0254

2030.0254

Schurter

FUSE BRD MNT 2A 125VAC/VDC RAD

0

2020.0006

2020.0006

Schurter

FUSE CRTRDGE 1.6A 250VAC 5X20MM

0

2030.0548

2030.0548

Schurter

FUSE BRD MNT 710MA 125VAC/VDC

0

2030.0018

2030.0018

Schurter

FUSE BRD MNT 710MA 125VAC/VDC

0

2030.0019

2030.0019

Schurter

FUSE BRD MNT 750MA 125VAC/VDC

0

2030.0249

2030.0249

Schurter

FUSE BRD MNT 750MA 125VAC/VDC

0

2010.0021

2010.0021

Schurter

FUSE CRTRDGE 2.5A 250VAC 5X20MM

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems