Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
1301.0074

1301.0074

Schurter

FUSE INDICATING FUSE 20A 500VAC

6

1301.0077

1301.0077

Schurter

FUSE INDICATING FUSE 40A 500VAC

6

8020.2062

8020.2062

Schurter

FUSE CARTRIDGE 20A 275VAC/1KVDC

34

0001.2029

0001.2029

Schurter

FUSE CARTRIDGE 40A 500VAC DT III

50

0090.0015

0090.0015

Schurter

FUSE CARTRIDGE 15A 1KVDC 5AG

436

8020.2086

8020.2086

Schurter

FUSE CARTRIDGE 25A 275VAC/1KVDC

47

0090.0001

0090.0001

Schurter

FUSE CARTRIDGE 1A 1KVDC 5AG

6

8020.2092

8020.2092

Schurter

FUSE CARTRIDGE 20A 275VAC/1KVDC

200

8020.2055

8020.2055

Schurter

FUSE CARTRIDGE 50A 275VAC/800VDC

33

1301.0081

1301.0081

Schurter

FUSE 100A 500V NH-DIN 00C

12

0090.1004

0090.1004

Schurter

FUSE CARTRIDGE 4A 1KVDC 5AG

55

0001.2025

0001.2025

Schurter

FUSE CARTRIDGE 16A 500VAC

103

0034.1107

0034.1107

Schurter

FUSE CARTRIDGE 25A 500VAC GLD II

25

0034.1104

0034.1104

Schurter

FUSE CARTRIDGE 10A 500VAC GLD II

25

8020.2054

8020.2054

Schurter

FUSE CARTRIDGE 40A 275VAC/800VDC

100

0090.1012

0090.1012

Schurter

FUSE CARTRIDGE 12A 1KVDC 5AG

12

8020.2050

8020.2050

Schurter

FUSE CARTRIDGE 10A 275VAC/1KVDC

80

8020.2051

8020.2051

Schurter

FUSE CARTRIDGE 15A 275VAC/1KVDC

38

0090.1025

0090.1025

Schurter

FUSE CARTRIDGE 25A 1KVDC 5AG

0

0001.2012

0001.2012

Schurter

FUSE CARTRIDGE 10A 250VAC DT I

50

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top