Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1G12UM

1G12UM

Altech Corporation

1G12UM 12A CIRCUIT BREAKER G CHA

12

1BU32R

1BU32R

Altech Corporation

1BU32R 32A MCB B CHAR 1P277VACUL

36

MMS-63H-40A

MMS-63H-40A

Altech Corporation

MANUAL MOTOR START 50KA 28-40A

0

GFL2D20300SN

GFL2D20300SN

Altech Corporation

MCCB+EGFP 20A120240V AC 300MA D

0

2G50UM

2G50UM

Altech Corporation

2G50UM 50A CIRCUIT BREAKER G CHA

6

GFR2B10010

GFR2B10010

Altech Corporation

EGFP+OL 10A277V AC 10MA B TRIP 1

4

3DU8R

3DU8R

Altech Corporation

3DU8R 8AMCBDCHAR3P 480Y/277VACUL

0

GFL2C13100SN

GFL2C13100SN

Altech Corporation

MCCB+EGFP 13A120240V AC 100MA C

0

2G03UM

2G03UM

Altech Corporation

2G03UM 0.3A CIRCUIT BREAKER G CH

0

1C1.6DL

1C1.6DL

Altech Corporation

1C1.6DL 1.6A CIRCUIT BREAKER C C

0

UV110DCL

UV110DCL

Altech Corporation

CIRCUIT BREAK UNDERVOLT 110VDC

0

3E13UM

3E13UM

Altech Corporation

3E13UM 13A CIRCUIT BREAKER ECHAR

0

US-6

US-6

Altech Corporation

MC SURGE UNIT VARISTOR + RC 200

0

1E5UM

1E5UM

Altech Corporation

1E5UM 5A CIRCUIT BREAKER 3 CHAR

12

GFL2D10100SN

GFL2D10100SN

Altech Corporation

MCCB+EGFP 10A120240V AC 100MA D

0

GFL2D30100S

GFL2D30100S

Altech Corporation

MCCB+EGFP 30A120240V AC 100MA D

0

1D50UL

1D50UL

Altech Corporation

1D50UL 50A CIRCUIT BREAKER D CHA

0

3CU05R

3CU05R

Altech Corporation

3CU05R0.5AMCBCCHAR3P 480Y/277VAC

4

1D05UL

1D05UL

Altech Corporation

1D05UL 0.5A CIRCUIT BREAKER D CH

0

GFR2C32030

GFR2C32030

Altech Corporation

EGFP+OL 32A277V AC 30MA C TRIP 1

2

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top