Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFR2C10100

GFR2C10100

Altech Corporation

EGFP+OL 10A277V AC 100MA C TRIP

1

GFL2D20100S

GFL2D20100S

Altech Corporation

MCCB+EGFP 20A120240V AC 100MA D

0

GFL2B16100SN

GFL2B16100SN

Altech Corporation

MCCB+EGFP 16A120240V AC 100MA B

0

1Z3UM

1Z3UM

Altech Corporation

1Z3UM 3A CIRCUIT BREAKER Z CHAR

120

3ZU30L

3ZU30L

Altech Corporation

3ZU30L30AMCBZCHAR3P 480Y/277VACU

0

3D32UL

3D32UL

Altech Corporation

3D32UL 32A CIRCUIT BREAKER D CHA

0

3D50UR

3D50UR

Altech Corporation

3D50UR 50A MCB D CHAR 3 P 480Y/2

40

1C30UM

1C30UM

Altech Corporation

1C30UM 30A CIRCUIT BREAKER C CHA

0

1DU05L

1DU05L

Altech Corporation

1DU05L 0.5A MCB D CHAR 1P277VACU

0

GFL2B40100SN

GFL2B40100SN

Altech Corporation

MCCB+EGFP 40A120240V AC 100MA B

0

1DU13R

1DU13R

Altech Corporation

1DU13R13A MCB D CHAR 1P277VACUL1

0

1G05UM

1G05UM

Altech Corporation

1G05UM0.5A CIRCUIT BREAKER G CHA

0

3Z2.5UM

3Z2.5UM

Altech Corporation

3Z2.5UM 2.5A CIRCUIT BREAKER Z C

0

GFR2C08100

GFR2C08100

Altech Corporation

EGFP+OL 8A277V AC 100MA C TRIP 1

0

2D2UR

2D2UR

Altech Corporation

2D2UR 2A MCB D CHAR 2 P 480Y/277

0

1D1DL

1D1DL

Altech Corporation

1D1DL 1A CIRCUIT BREAKER D CHAR

0

GFR4B06100

GFR4B06100

Altech Corporation

EGFP+OL 6A480Y277V AC 100MA B TR

0

TR11-C-X-63-B-0-C-0.9A

TR11-C-X-63-B-0-C-0.9A

Altech Corporation

CIRCUIT BREAK TRIP BAND HEX MET

0

DC1DU1.6L

DC1DU1.6L

Altech Corporation

16A MCB D CHAR 1P125VDCUL489

0

2Z15UL

2Z15UL

Altech Corporation

2Z15UL 15A CIRCUIT BREAKER Z CHA

5

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top