Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
2DU63L

2DU63L

Altech Corporation

2DU63L63A MCBDCHAR2P 240V ACUL48

0

3DU63R

3DU63R

Altech Corporation

3DU63R 63AMCBDCHAR3 P 480Y/277VA

0

3C2UL

3C2UL

Altech Corporation

3C2UL 2A CIRCUIT BREAKER C CHAR3

32

2DU60L

2DU60L

Altech Corporation

2DU60L60A MCBDCHAR2P 240V ACUL48

120

GFL2C081002

GFL2C081002

Altech Corporation

MCCB+EGFP 8A240V AC 100MA C TRIP

0

GFR4B13300

GFR4B13300

Altech Corporation

EGFP+OL 13A480Y277V AC 300MA B T

0

DC1DU10L

DC1DU10L

Altech Corporation

10A MCB D CHAR 1P125VDCUL489

180

GFL2D153002

GFL2D153002

Altech Corporation

MCCB+EGFP 15A240V AC 300MA D TRI

0

GFR2B16300

GFR2B16300

Altech Corporation

EGFP+OL 16A277V AC 300MA B TRIP

0

DC1CU6L

DC1CU6L

Altech Corporation

DC1CU6L60A MCB C CHAR 1P125VDCUL

0

GFL2D15030S

GFL2D15030S

Altech Corporation

MCCB+EGFP 15A120240V AC 30MA D T

0

3G6UM

3G6UM

Altech Corporation

3G6UM 6ACIRCUIT BREAKER G CHAR3P

0

GFR2B25030

GFR2B25030

Altech Corporation

EGFP+OL 25A277V AC 30MA B TRIP 1

6

1Z13UM

1Z13UM

Altech Corporation

1Z13UM 13A CIRCUIT BREAKER Z CHA

0

1C5DL

1C5DL

Altech Corporation

1C5DL 5A CIRCUIT BREAKER C CHAR

0

2B1.6UM

2B1.6UM

Altech Corporation

2B1.6UM 1.6A CIRCUIT BREAKER B C

0

1C32UM

1C32UM

Altech Corporation

1C32UM 32A CIRCUIT BREAKER C CHA

12

GFL2B05010SN

GFL2B05010SN

Altech Corporation

MCCB+EGFP 5A120240V AC 10MA B TR

0

TR11-C-X-63-B-0-C-3.0A

TR11-C-X-63-B-0-C-3.0A

Altech Corporation

CIRCUIT BREAK BLK SLIDERNOTBHEX

60

GFL2D151002

GFL2D151002

Altech Corporation

MCCB+EGFP 15A240V AC 100MA D TRI

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure