Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFR2B13030

GFR2B13030

Altech Corporation

EGFP+OL 13A277V AC 30MA B TRIP 1

0

GFL2B25100S

GFL2B25100S

Altech Corporation

MCCB+EGFP 25A120240V AC 100MA B

0

GFR2B15030

GFR2B15030

Altech Corporation

EGFP+OL 15A277V AC 30MA B TRIP 1

13

GFL2D10010S

GFL2D10010S

Altech Corporation

MCCB+EGFP 10A120240V AC 10MA D T

0

GFL2C08030S

GFL2C08030S

Altech Corporation

MCCB+EGFP 8A120240V AC 30MA C TR

0

UV120ACR

UV120ACR

Altech Corporation

CIRCUIT BREAK UNDERVOLT 120VAC

0

GFL2D12030SN

GFL2D12030SN

Altech Corporation

MCCB+EGFP 12A120240V AC 30MA D T

0

1G125UM

1G125UM

Altech Corporation

1G125UM 12.5A CIRCUIT BREAKER G

0

DC2CU13L

DC2CU13L

Altech Corporation

DC2CU13L13A MCB CCHAR 2P 250VDC

0

GFL2C15010S

GFL2C15010S

Altech Corporation

MCCB+EGFP 15A120240V AC 10MA C T

0

GF263300

GF263300

Altech Corporation

EGFP 63A277V AC 300MA 1P+N 5060H

0

1D32UM

1D32UM

Altech Corporation

1D32UM 32A CIRCUIT BREAKER D CHA

0

2Z05UM

2Z05UM

Altech Corporation

2Z05UM 0.5A CIRCUIT BREAKER Z CH

0

1G63UM

1G63UM

Altech Corporation

1G63UM 63A CIRCUIT BREAKER G CHA

0

GFL2C101002

GFL2C101002

Altech Corporation

MCCB+EGFP 10A240V AC 100MA C TRI

0

2G8UM

2G8UM

Altech Corporation

2G8UM 8A CIRCUIT BREAKER G CHAR2

48

2Z15UM

2Z15UM

Altech Corporation

2Z15UM 15A CIRCUIT BREAKER Z CHA

0

1CU16L

1CU16L

Altech Corporation

1CU16L16A MCB C CHAR 1P277VACUL4

24

GFL2D060102

GFL2D060102

Altech Corporation

MCCB+EGFP 6A240V AC 10MA D TRIP

0

2D8DL

2D8DL

Altech Corporation

CIRCUIT BREAKER 8A 2P UL489

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure