Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1D35DL

1D35DL

Altech Corporation

1D35DL 35A CIRCUIT BREAKER D CHA

36

GFL2B25300S

GFL2B25300S

Altech Corporation

MCCB+EGFP 25A120240V AC 300MA B

0

S-TS400NU-FTU-LL-400

S-TS400NU-FTU-LL-400

Altech Corporation

CIRCUIT BREAKER 400A480V AC 3P 3

0

GFL2C20100S

GFL2C20100S

Altech Corporation

MCCB+EGFP20A120240V AC100MA C TR

0

3D25UM

3D25UM

Altech Corporation

3D25UM 25A CIRCUIT BREAKER D CHA

0

2CU1L

2CU1L

Altech Corporation

2CU1L1.0A MCBCCHAR2P 480Y/277VAC

42

3CU15R

3CU15R

Altech Corporation

3CU15R15AMCBCCHAR3P 480Y/277VACU

24

GFL2B103002

GFL2B103002

Altech Corporation

MCCB+EGFP 10A240V AC 300MA B TRI

0

1E30UM

1E30UM

Altech Corporation

1E30UM 30ACIRCUIT BREAKER E CHAR

0

MA063UM

MA063UM

Altech Corporation

MA063UM 040-063A 3P MOTORPROTECT

0

DC1DU13L

DC1DU13L

Altech Corporation

13A MCB D CHAR 1P125DCUL489

0

GFL2C25100S

GFL2C25100S

Altech Corporation

MCCB+EGFP 25A120240V AC 100MA C

0

GFL2C20030SN

GFL2C20030SN

Altech Corporation

MCCB+EGFP 20A120240V AC 30MA C T

0

GFL2D050102

GFL2D050102

Altech Corporation

MCCB+EGFP 5A240V AC 10MA D TRIP

6

1D40DL

1D40DL

Altech Corporation

1D40DL 40A CIRCUIT BREAKER D CHA

0

RP4430

RP4430

Altech Corporation

FI4430 63A 300MA 4P EARTH LEAKAG

0

2C16UR

2C16UR

Altech Corporation

2C16UR 16A MCB C CHAR 2 P 480Y/2

6

2D20UR

2D20UR

Altech Corporation

2D20UR 20A MCB D CHAR 2 P 480Y/2

12

2B25UR

2B25UR

Altech Corporation

2B25UR 25A MCB B CHAR 2 P 480Y/2

30

2B5UR

2B5UR

Altech Corporation

2B5UR 5A MCB B CHAR 2 P 480Y/277

12

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure