Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFR2B10100

GFR2B10100

Altech Corporation

EGFP+OL 10A277V AC 100MA B TRIP

0

3G16UM

3G16UM

Altech Corporation

3G16UM 16ACIRCUIT BREAKER G CHAR

0

GFL2C05030SN

GFL2C05030SN

Altech Corporation

MCCB+EGFP5A120240V AC30MA D TRIP

0

UTS150N-FTU-80

UTS150N-FTU-80

Altech Corporation

CIRCUIT BREAKER 80A/480V AC 3P 3

0

1C40UR

1C40UR

Altech Corporation

1C40UR 40A MCB C CHAR 1 P 277VAC

48

1B20UR

1B20UR

Altech Corporation

1B20UR 20A MCB B CHAR 1 P 277VAC

12

3D32UM

3D32UM

Altech Corporation

3D32UM 32A CIRCUIT BREAKER D CHA

0

GFL2B12010SN

GFL2B12010SN

Altech Corporation

MCCB+EGFP 12A120240V AC 10MA B T

0

N32UL

N32UL

Altech Corporation

N32UL NEUTRALP UL489 03-32A 277V

0

2CU12L

2CU12L

Altech Corporation

2CU12L12A MCBCCHAR2P 480Y/277VAC

198

2B20UM

2B20UM

Altech Corporation

2B20UM 20A CIRCUIT BREAKER B CHA

0

GFR4D12100

GFR4D12100

Altech Corporation

EGFP+OL 12A480Y277V AC 100MA D T

0

3D30UR

3D30UR

Altech Corporation

3D30UR 30A MCB D CHAR 3 P 480Y/2

12

3C30UR

3C30UR

Altech Corporation

3C30UR 30A MCB C CHAR 3 P 480Y/2

4

2DU30R

2DU30R

Altech Corporation

2DU30R30A MCBDCHAR2P 480Y/277VAC

36

DC2CU1L

DC2CU1L

Altech Corporation

DC2CU1L10A MCB CCHAR 2P 250VDC U

18

2C16DL

2C16DL

Altech Corporation

2C16DL 16A CIRCUIT BREAKER C CHA

0

2D40UL

2D40UL

Altech Corporation

CIRCUIT BREAKER 40A 2P UL489

6

2E12UM

2E12UM

Altech Corporation

2E12UM 12A CIRCUIT BREAKER E CHA

0

1D25UL

1D25UL

Altech Corporation

1D25UL 25A CIRCUIT BREAKER D CHA

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure