Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFR2D16300

GFR2D16300

Altech Corporation

EGFP+OL 16A277V AC 300MA D TRIP

0

US-14

US-14

Altech Corporation

SURGE UNIT VARISTOR 380 440VACDC

0

GFR4D30300

GFR4D30300

Altech Corporation

EGFP+OL 30A480Y277V AC 300MA D T

0

2G12UM

2G12UM

Altech Corporation

2G12UM 12A CIRCUIT BREAKER G CHA

12

3Z03UM

3Z03UM

Altech Corporation

3Z03UM 0.3A CIRCUIT BREAKER Z CH

0

1D32UR

1D32UR

Altech Corporation

1D32UR 32A MCB D CHAR 1 P 277VAC

12

3Z12UM

3Z12UM

Altech Corporation

3Z12UM 12A CIRCUIT BREAKER Z CHA

0

1D15DL

1D15DL

Altech Corporation

1D15DL 15A CIRCUIT BREAKER D CHA

0

3D40UR

3D40UR

Altech Corporation

3D40UR 40A MCB D CHAR 3 P 480Y/2

0

3BU10R

3BU10R

Altech Corporation

3BU10R10AMCBBCHAR3P 480Y/277VACU

16

2C2.5UM

2C2.5UM

Altech Corporation

2C2.5UM 2.5A CIRCUIT BREAKER C C

0

3DU5R

3DU5R

Altech Corporation

3DU5R 5AMCBDCHAR3P 480Y/277VACUL

68

3CU5R

3CU5R

Altech Corporation

3CU5R5AMCBCCHAR3P 480Y/277VACUL1

116

UV48DCR

UV48DCR

Altech Corporation

CIRCUIT BREAK UNDERVOLT 48V DC C

0

TR11-C-X-63-B-1-C-1.0A

TR11-C-X-63-B-1-C-1.0A

Altech Corporation

CIRCUIT BREAK TPBDVERMAHEX METNU

0

GFR2C16010

GFR2C16010

Altech Corporation

EGFP+OL 16A277V AC 10MA C TRIP 1

0

GFR4D32030

GFR4D32030

Altech Corporation

EGFP+OL 32A480Y277V AC 30MA D TR

0

GFR4D05030

GFR4D05030

Altech Corporation

EGFP+OL 5A480Y277V AC 30MA D TRI

0

3E075UM

3E075UM

Altech Corporation

3E075UM 0.75ACIRCUIT BREAKER ECH

0

2B4UR

2B4UR

Altech Corporation

2B4UR 4A MCB B CHAR 2 P 480Y/277

24

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure