Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1D16UL

1D16UL

Altech Corporation

1D16UL 16A CIRCUIT BREAKER D CHA

12

3G32UM

3G32UM

Altech Corporation

3G32UM 32ACIRCUIT BREAKER G CHAR

0

GFR4D16030

GFR4D16030

Altech Corporation

EGFP+OL 16A480Y277V AC 30MA D TR

0

GFL2B05030S

GFL2B05030S

Altech Corporation

MCCB+EGFP 5A120240V AC 30MA B TR

0

2Z1UM

2Z1UM

Altech Corporation

2Z1UM 1A CIRCUIT BREAKER Z CHAR2

6

3D1UM

3D1UM

Altech Corporation

3D1UM 1ACIRCUIT BREAKER D CHAR3P

0

GFL2D160302

GFL2D160302

Altech Corporation

MCCB+EGFP 16A240V AC 30MA D TRIP

0

GFL2B10030S

GFL2B10030S

Altech Corporation

MCCB+EGFP 10A120240V AC 30MA B T

0

2C5UR

2C5UR

Altech Corporation

2C5UR 5A MCB C CHAR 2 P 480Y/277

6

MMS-63H-10A

MMS-63H-10A

Altech Corporation

MANUAL MOTOR START 65KA 6-10A

0

2D8UR

2D8UR

Altech Corporation

2D8UR 8A MCB D CHAR 2 P 480Y/277

0

DC1CU60L

DC1CU60L

Altech Corporation

DC1CU60L60A MCB C CHAR 1P125VDCU

0

GFR2C05100

GFR2C05100

Altech Corporation

EGFP+OL 5A277V AC 100MA C TRIP 1

4

2G05UM

2G05UM

Altech Corporation

2G05UM 0.5A CIRCUIT BREAKER G CH

0

1CU02L

1CU02L

Altech Corporation

1CU02L0.2A MCB C CHAR 1P277VACUL

12

1Z50UL

1Z50UL

Altech Corporation

1Z50UL 50A CIRCUIT BREAKER Z CHA

12

1Z40UM

1Z40UM

Altech Corporation

1Z40UM 40A CIRCUIT BREAKER Z CHA

0

3B60UM

3B60UM

Altech Corporation

CIRCUIT BREAKER60UM 60A B CHAR3P

0

3B20UR

3B20UR

Altech Corporation

CIRCUIT BREAKER20UR 20A MCB B CH

180

1CU60L

1CU60L

Altech Corporation

1CU60L60A MCB C CHAR 1P240VACUL4

12

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure