Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
3E30UM

3E30UM

Altech Corporation

3E30UM 30A CIRCUIT BREAKER ECHAR

4

2E50UM

2E50UM

Altech Corporation

2E50UM 50A CIRCUIT BREAKER E CHA

0

2CU20R

2CU20R

Altech Corporation

2CU20R 20A MCBCCHAR2P 480Y/277VA

12

GFL2C060302

GFL2C060302

Altech Corporation

MCCB+EGFP 6A240V AC 30MA C TRIP

6

RP2330

RP2330

Altech Corporation

RP2330 40A 300MA 2P EARTH LEAKAG

0

GFR2D40030

GFR2D40030

Altech Corporation

EGFP+OL 40A277V AC 30MA D TRIP 1

0

GFL2D30300SN

GFL2D30300SN

Altech Corporation

MCCB+EGFP 30A120240V AC 300MA D

0

2BU8R

2BU8R

Altech Corporation

2BU8R 8A MCBBCHAR2P 480Y/277VACU

0

GFL2D16100S

GFL2D16100S

Altech Corporation

MCCB+EGFP 16A120240V AC 100MA D

0

3E03UM

3E03UM

Altech Corporation

3E03UM 0.3A CIRCUIT BREAKER ECHA

0

UTE100N-FTU-60

UTE100N-FTU-60

Altech Corporation

CIRCUIT BREAKER 60A/480V AC 3P 3

0

3BU3R

3BU3R

Altech Corporation

3BU3R3AMCBBCHAR3P 480Y/277VACUL1

0

GFL2D150302

GFL2D150302

Altech Corporation

MCCB+EGFP 15A240V AC 30MA D TRIP

24

GFL2D06100SN

GFL2D06100SN

Altech Corporation

MCCB+EGFP 6A120240V AC 100MA D T

0

1G8UM

1G8UM

Altech Corporation

1G8UM 8A CIRCUIT BREAKER G CHAR

0

GFL2C250102

GFL2C250102

Altech Corporation

MCCB+EGFP 25A240V AC 10MA C TRIP

0

DC1CU10L

DC1CU10L

Altech Corporation

DC1CU10L10A MCB C CHAR 1P125VDCU

0

2CU25L

2CU25L

Altech Corporation

2CU25L25A MCBCCHAR2P 480Y/277VAC

318

GFL2D25100SN

GFL2D25100SN

Altech Corporation

MCCB+EGFP 25A120240V AC 100MA D

0

2G3UM

2G3UM

Altech Corporation

2G3UM 3A CIRCUIT BREAKER G CHAR2

24

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top