Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFR4B16100

GFR4B16100

Altech Corporation

EGFP+OL 16A480Y277V AC 100MA B T

0

1BU6R

1BU6R

Altech Corporation

1BU6R 6A MCB B CHAR 1P277VACUL10

0

GFL2B253002

GFL2B253002

Altech Corporation

MCCB+EGFP 25A240V AC 300MA B TRI

0

1C50UR

1C50UR

Altech Corporation

1C50UR 50A MCB C CHAR 1 P 277VAC

0

GFL2D200302

GFL2D200302

Altech Corporation

MCCB+EGFP 20A240V AC 30MA D TRIP

0

1C15UM

1C15UM

Altech Corporation

1C15UM 15ACIRCUIT BREAKER C CHAR

0

MMS-100H-40A

MMS-100H-40A

Altech Corporation

MANUAL MOTOR START 65KA 28-40A

0

3D63UR

3D63UR

Altech Corporation

3D63UR 63A MCB D CHAR 3 P 480Y/2

0

DC2DU15L

DC2DU15L

Altech Corporation

DC2DU15L15A MCBDCHAR 2P250VDCUL4

0

1C4UM

1C4UM

Altech Corporation

1C4UM 4A CIRCUIT BREAKER C CHAR

120

3Z6UM

3Z6UM

Altech Corporation

3Z6UM 6A CIRCUIT BREAKER Z CHAR3

0

DC2CU4L

DC2CU4L

Altech Corporation

DC2CU4L40A MCB CCHAR 2P 250VDC U

6

3BU4R

3BU4R

Altech Corporation

3BU4R4AMCBBCHAR3P 480Y/277VACUL1

0

S-TS250NU-FTU-LL-200

S-TS250NU-FTU-LL-200

Altech Corporation

CIRCUIT BREAKER 200A480V AC 3P 3

0

2B1UM

2B1UM

Altech Corporation

2B1UM 1A CIRCUIT BREAKER B CHAR2

0

3C03UM

3C03UM

Altech Corporation

3C03UM 0.3A CIRCUIT BREAKER C CH

0

GFR2D08100

GFR2D08100

Altech Corporation

EGFP+OL 8A277V AC 100MA D TRIP 1

0

GFL2D253002

GFL2D253002

Altech Corporation

MCCB+EGFP 25A240V AC 300MA D TRI

12

MS025

MS025

Altech Corporation

MS025 MANUAL MOTOR CONTROLLER 01

0

1B15UM

1B15UM

Altech Corporation

1B15UM 15A CIRCUIT BREAKER B CHA

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure