Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4420.0248

4420.0248

Schurter

CIR BRKR THRM MAG 15A 277V 65V

4

4435.0597

4435.0597

Schurter

CIR BRKR THRM 300MA 240VAC 32VDC

18

4435.0268

4435.0268

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

0

4400.0189

4400.0189

Schurter

CIR BRKR THRM 2A 240VAC 48VDC

0

4430.3667

4430.3667

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

0

4404.0023

4404.0023

Schurter

CIR BRKR THRM 12A 240VAC 48VDC

400300

4435.0507

4435.0507

Schurter

CIR BRKR THRM 16A 240VAC 32VDC

38

4420.0276

4420.0276

Schurter

CIR BRKR THRM MAG 15A 480V 65V

0

4435.0101

4435.0101

Schurter

CIR BRKR THRM 240VAC 32VDC

20

4435.0041

4435.0041

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

79

4400.0042

4400.0042

Schurter

CIR BRKR THRM 800MA 240VAC 48VDC

55

4430.2781

4430.2781

Schurter

CIR BRKR THRM 240VAC 60VDC

10

4435.0324

4435.0324

Schurter

CIR BRKR THRM 240VAC 32VDC

20

4420.0301

4420.0301

Schurter

CIR BRKR THRM MAG 5A 480V 65V

7

4400.0185

4400.0185

Schurter

CIR BRKR THRM 4A 240VAC 48VDC

0

TS-701-HT-8K

TS-701-HT-8K

Schurter

CIR BRKR THRM 8A 250VAC 50VDC

100

4435.0073

4435.0073

Schurter

CIR BRKR THRM 20A 240VAC 32VDC

29

4400.01

4400.01

Schurter

CIR BRKR THRM 13A 240VAC 48VDC

0

4404.0018

4404.0018

Schurter

CBE T9-611P-3

133

TS-709-15K

TS-709-15K

Schurter

CIR BRKR THRM 15A 250VAC 50VDC

52

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure