Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0287

4435.0287

Schurter

CIR BRKR THRM 240VAC ROTARY

16

4400.0019

4400.0019

Schurter

CIR BRKR THRM 1A 240VAC 48VDC

84

4430.1472

4430.1472

Schurter

CIR BRKR THRM 3.8A 240VAC 60VDC

20

4435.0084

4435.0084

Schurter

CIR BRKR THRM 50MA 240VAC 32VDC

15

4430.0590

4430.0590

Schurter

CIR BRK THRMAL 3.5A 240VAC/60VDC

3

4420.0675

4420.0675

Schurter

CIR BRKR THRM MAG 15A 277V 65V

2

4420.0569

4420.0569

Schurter

CIR BRKR THRM MAG 15A 480V 65V

4

4400.0059

4400.0059

Schurter

CIR BRKR THRM 500MA 240VAC 48VDC

55

4435.007

4435.007

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4430.0545

4430.0545

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

20

4430.3552

4430.3552

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

11

4435.0284

4435.0284

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

0

4430.3647

4430.3647

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

15

4435.0364

4435.0364

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

8

4435.0181

4435.0181

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

6

4420.0297

4420.0297

Schurter

CIR BRKR THRM MAG 32A 480V 65V

3

4430.2599

4430.2599

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

20

4435.0502

4435.0502

Schurter

CIR BRKR THRM 3.5A 240VAC 32VDC

12

4404.0103

4404.0103

Schurter

CIRC BREAKER PCB MNT 12A

0

4435.0336

4435.0336

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

10

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure