Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0401

4435.0401

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

9

4435.0176

4435.0176

Schurter

CIR BRKR THRM 5A 240VAC 32VDC

4

4435.0503

4435.0503

Schurter

CIR BRKR THRM 4A 240VAC 32VDC

6

4435.0211

4435.0211

Schurter

CIR BRKR THRM 500MA 240VAC 60VDC

4

4420.0228

4420.0228

Schurter

CIR BRKR THRM MAG 8A 277V 65V

5

4435.0304

4435.0304

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

0

3-100-114

3-100-114

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

20

4420.0317

4420.0317

Schurter

CIR BRKR THRM MAG 7A 480V 65V

14

4430.0385

4430.0385

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4435.0332

4435.0332

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

7

4400.0711

4400.0711

Schurter

CIR BRKR THRM 2A 240VAC 48VDC

0

4410.9001

4410.9001

Schurter

CIR BRKR THRM 10A 240VAC 28VDC

152

4420.028

4420.028

Schurter

CIR BRKR THRM MAG 25A 360 VDC

0

4404.0031

4404.0031

Schurter

CIR BRKR THRM 8A 240VAC 48VDC

100

TS-701-HT-20

TS-701-HT-20

Schurter

CIR BRKR THRM 20A 250VAC 50VDC

155

4430.3472

4430.3472

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

8

TS-701-HT-35

TS-701-HT-35

Schurter

CIR BRKR THRM 35A 250VAC 50VDC

246200

4435.0325

4435.0325

Schurter

CIR BRKR THRM 240VAC 60VDC

20

4435.0197

4435.0197

Schurter

CIR BRKR THRM 1A 240VAC 32VDC

0

4435.0106

4435.0106

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

4

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top