Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4430.1729

4430.1729

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

12

4435.0212

4435.0212

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

9

4435.0333

4435.0333

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

5

4430.3091

4430.3091

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

10

4404.0001

4404.0001

Schurter

CIR BRKR THRM 4A 240VAC 48VDC

1008400

4430.1133

4430.1133

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

20

4430.1201

4430.1201

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

119160

4435.0423

4435.0423

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

11

4430.0586

4430.0586

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

20

4435.0256

4435.0256

Schurter

CIR BRKR THRM 20A 240VAC 32VDC

0

4435.0285

4435.0285

Schurter

CIR BRKR THRM 2A 240VAC ROCKER

10

4420.0223

4420.0223

Schurter

CIR BRKR THRM MAG 30A 480V 65V

1

4430.0005

4430.0005

Schurter

CIR BRKR THRM 700MA 240VAC 60VDC

19

4430.3634

4430.3634

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

15

4411.0014

4411.0014

Schurter

CIR BRKR THRM 5A 277VAC 28VDC

18

4430.23

4430.23

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

118

4430.0977

4430.0977

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

16

4430.2867

4430.2867

Schurter

CIR BRKR THRM 240VAC 60VDC

1415

4435.0573

4435.0573

Schurter

CIR BRKR THRM 2A 240VAC 32VDC

39

4430.3377

4430.3377

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

20

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure