Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0351

4435.0351

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

4

4435.0081

4435.0081

Schurter

CIR BRKR THRM 20A 240VAC 32VDC

0

4435.0104

4435.0104

Schurter

CIR BRKR THRM 240VAC 60VDC

10

4435.026

4435.026

Schurter

CIR BRKR THRM 15A 240VAC 32VDC

0

3-101-227

3-101-227

Schurter

CIR BRKR THRM 5A 240VAC 48VDC

0

4435.0091

4435.0091

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4435.0275

4435.0275

Schurter

CIR BRKR THRM 2.5A 240VAC 60VDC

17

4435.0012

4435.0012

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4404.0049

4404.0049

Schurter

CBE T9-311C-3

451

4400.0026

4400.0026

Schurter

CIR BRKR THRM 5A 240VAC 48VDC

47100

4420.0169

4420.0169

Schurter

CIR BRKR THRM MAG 8A 480V 65V

0

4420.0323

4420.0323

Schurter

CIR BRKR THRM MAG 32A 480V 65V

0

4435.0198

4435.0198

Schurter

CIR BRKR THRM 1.5A 240VAC 32VDC

71

4400.0573

4400.0573

Schurter

CIR BRKR THRM 600MA 240VAC 48VDC

0

4430.0444

4430.0444

Schurter

CIR BRKR THRM 8.5A 240VAC 60VDC

9

TS-701-HT-12

TS-701-HT-12

Schurter

CIR BRKR THRM 12A 250VAC 50VDC

12

4404.0005

4404.0005

Schurter

CIR BRKR THRM 12A 240VAC 48VDC

150

4410.0031

4410.0031

Schurter

CIR BRKR THRM 4A 240VAC 28VDC

15

4400.018

4400.018

Schurter

CIR BRKR THRM 3.5A 240VAC 48VDC

0

4435.0596

4435.0596

Schurter

CIR BRKR THRM 200MA 240VAC 32VDC

14

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure