Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0033

4435.0033

Schurter

CIR BRKR THRM 13A 240VAC 60VDC

10

4435.0021

4435.0021

Schurter

CIR BRKR THRM 50MA 240VAC 32VDC

7

4400.0047

4400.0047

Schurter

CIR BRKR THRM 2A 240VAC 48VDC

102

4404.0096

4404.0096

Schurter

CIRC BREAKER PCB MNT 3A

234300

4430.3891

4430.3891

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

0

4430.3494

4430.3494

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

15

4435.0272

4435.0272

Schurter

CIR BRKR THRM 8A 240VAC 60VDC

10

4430.2802

4430.2802

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

12

4435.0226

4435.0226

Schurter

CIR BRKR THRM 500MA 240VAC

5

3-101-228

3-101-228

Schurter

CIR BRKR THRM 4A 240VAC 48VDC

194

4420.0221

4420.0221

Schurter

CIR BRKR THRM MAG 30A 480V 65V

0

4430.2319

4430.2319

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

20

4400.0308

4400.0308

Schurter

CIR BRKR THRM 400MA 240VAC 48VDC

0

4435.0116

4435.0116

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

2

4400.0006

4400.0006

Schurter

CIR BRKR THRM 5A 240VAC 48VDC

415200

4430.0035

4430.0035

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

7

4420.0724

4420.0724

Schurter

CIR BRKR THRM MAG 9A 480V 65V

0

4404.0032

4404.0032

Schurter

CIR BRKR THRM 10A 240VAC 48VDC

100

4430.1384

4430.1384

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

16

4430.2259

4430.2259

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure