Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4430.0024

4430.0024

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

9

4435.0242

4435.0242

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

20

4435.0349

4435.0349

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

10

4430.3456

4430.3456

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

15

4430.2792

4430.2792

Schurter

CIR BRKR THRM 500MA 240VAC 60VDC

20

4400.0025

4400.0025

Schurter

CIR BRKR THRM 4A 240VAC 48VDC

83

4435.0405

4435.0405

Schurter

CIR BRKR THRM 3.5A 240VAC 60VDC

10

4430.1624

4430.1624

Schurter

CIR BRKR THRM 1.2A 240VAC 60VDC

18

4435.0279

4435.0279

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

8

4430.1089

4430.1089

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

300

4400.0015

4400.0015

Schurter

CIR BRKR THRM 8A 240VAC 48VDC

122

4420.0242

4420.0242

Schurter

CIR BRKR THRM MAG 25A 480V 65V

0

4430.1638

4430.1638

Schurter

CIR BRKR THRM 2.5A 240VAC 60VDC

20

4435.0393

4435.0393

Schurter

CIR BRKR THRM 500MA 240VAC 60VDC

7

4435.0004

4435.0004

Schurter

CIR BRKR THRM 4A 240VAC 32VDC

549

4410.9008

4410.9008

Schurter

CIR BRKR THRM 16A 240VAC 28VDC

9

4400.0082

4400.0082

Schurter

CIR BRKR THRM 1A 240VAC 48VDC

0

3-101-230

3-101-230

Schurter

CIR BRKR THRM 10A 240VAC 48VDC

79

4439.0002

4439.0002

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

0

4400.0579

4400.0579

Schurter

CIR BRKR THRM 100MA 240VAC 48VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top