Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4404.002

4404.002

Schurter

CIR BRKR THRM 6A 240VAC 48VDC

58

4435.0008

4435.0008

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

4

4400.0569

4400.0569

Schurter

CIR BRKR THRM 2.3A 240VAC 48VDC

0

4400.0069

4400.0069

Schurter

CIR BRKR THRM 400MA 240VAC 48VDC

0

4430.2297

4430.2297

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

5

4420.0211

4420.0211

Schurter

CIR BRKR THRM MAG 3A 480V 65V

0

4435.0631

4435.0631

Schurter

CIR BRKR THRM 12A 240VAC 32VDC

0

4430.0542

4430.0542

Schurter

CIR BRKR THRM 1.5A 240VAC 60VDC

18

4430.0861

4430.0861

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4435.0023

4435.0023

Schurter

CIR BRKR THRM 2.8A 240VAC 60VDC

10

4435.0392

4435.0392

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

7

4411.0015

4411.0015

Schurter

CIR BRKR THRM 6A 277VAC 28VDC

19

4430.2612

4430.2612

Schurter

CIR BRKR THRM 200MA 240VAC 60VDC

18

4430.3308

4430.3308

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

9

4430.1353

4430.1353

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

98260

4430.3715

4430.3715

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

0

4430.2201

4430.2201

Schurter

CBE TA45-A023RC00U3

55

4420.0396

4420.0396

Schurter

CIR BRKR THRM MAG 7A 480V 65V

0

4430.2806

4430.2806

Schurter

CIR BRKR THRM 18A 240VAC 60VDC

0

4420.0576

4420.0576

Schurter

CIR BRKR THRM MAG 30A 480V 65V

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure