Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0177

4435.0177

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

5

4435.0577

4435.0577

Schurter

CIR BRKR THRM 800MA 240VAC 32VDC

11

4435.0796

4435.0796

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

5

4435.0249

4435.0249

Schurter

CIR BRKR THRM 240VAC 60VDC

10

4435.0183

4435.0183

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

7

4435.0567

4435.0567

Schurter

CIR BRKR THRM 8A 240VAC 32VDC

17

4400.0011

4400.0011

Schurter

CIR BRKR THRM 3.5A 240VAC 48VDC

88

4430.1146

4430.1146

Schurter

CIR BRKR THRM 240VAC 60VDC

0

4410.9013

4410.9013

Schurter

CIR BRKR THRM 10A 240VAC 28VDC

9

4420.0719

4420.0719

Schurter

CIR BRKR THRM MAG 10A 180 VDC

0

4430.0764

4430.0764

Schurter

CIR BRKR THRM 240VAC 60VDC

17

4430.2311

4430.2311

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

90140

4411.0109

4411.0109

Schurter

CIR BRKR THRM 10A 277VAC 28VDC

16

4400.0447

4400.0447

Schurter

CIR BRKR THRM 1A 240VAC 48VDC

0

4435.0182

4435.0182

Schurter

CIR BRKR THRM 15A 240VAC 32VDC

0

4435.0088

4435.0088

Schurter

CIR BRKR THRM 4A 240VAC 60VDC

18

4435.0378

4435.0378

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

0

4435.0368

4435.0368

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

9

4420.0402

4420.0402

Schurter

CIR BRKR THRM MAG 2A 480V 65V

0

4435.0147

4435.0147

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

10

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure