Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0246

4435.0246

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

9

4435.0024

4435.0024

Schurter

CIR BRKR THRM 50MA 240VAC 60VDC

5

4404.0003

4404.0003

Schurter

CIR BRKR THRM 8A 240VAC 48VDC

785100

4435.0569

4435.0569

Schurter

CIR BRKR THRM 14A 240VAC 32VDC

15

4410.0039

4410.0039

Schurter

CIR BRKR THRM 600MA 240VAC 28VDC

14

4420.0198

4420.0198

Schurter

CIR BRKR THRM MAG 20A 480V 65V

0

4411.0017

4411.0017

Schurter

CIR BRKR THRM 30A 277VAC 28VDC

42

4435.0026

4435.0026

Schurter

CIR BRKR THRM 2.8A 240VAC ROCKER

10

4430.3691

4430.3691

Schurter

CIR BRKR THRM 1.5A 240VAC 60VDC

15

4435.0215

4435.0215

Schurter

CIR BRKR THRM 2.5A 240VAC 60VDC

9

4430.3823

4430.3823

Schurter

CBE TA45-ABDWT200C0-AZM03

1

4430.2736

4430.2736

Schurter

CIR BRKR THRM 240VAC 60VDC

20

4404.0029

4404.0029

Schurter

CIR BRKR THRM 4A 240VAC 48VDC

64

4435.0195

4435.0195

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

0

4435.0077

4435.0077

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

16

4435.0009

4435.0009

Schurter

CIR BRKR THRM 4A 240VAC 60VDC

10

4435.0148

4435.0148

Schurter

CIR BRKR THRM 5A 240VAC ROCKER

9

4435.0292

4435.0292

Schurter

CIR BRKR THRM 2A 240VAC 32VDC

167

4435.0137

4435.0137

Schurter

CIR BRKR THRM 15A 240VAC 32VDC

0

4435.0579

4435.0579

Schurter

CIR BRKR THRM 400MA 240VAC 32VDC

1

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure