Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4400.0037

4400.0037

Schurter

CIR BRKR THRM 2A 240VAC 48VDC

0

4435.0213

4435.0213

Schurter

CIR BRKR THRM 1.5A 240VAC 60VDC

10

4435.0618

4435.0618

Schurter

CIR BRKR THRM 1A 240VAC 32VDC

19

4404.0097

4404.0097

Schurter

CIRC BREAKER PCB MNT 4A

118

4430.1563

4430.1563

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

5

4430.2085

4430.2085

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

20

4435.0371

4435.0371

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

6

4435.0068

4435.0068

Schurter

CIR BRKR THRM 9A 240VAC ROCKER

5

4404.0100

4404.0100

Schurter

CIRC BREAKER PCB MNT 7A

199

4435.0175

4435.0175

Schurter

CIR BRKR THRM 3A 240VAC 32VDC

20120

4435.0504

4435.0504

Schurter

CIR BRKR THRM 6A 240VAC 32VDC

20

4420.0532

4420.0532

Schurter

CIR BRKR THRM MAG 6A 480V 65V

0

4400.0148

4400.0148

Schurter

CIR BRKR THRM 200MA 240VAC 48VDC

9

4435.0352

4435.0352

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

4

4435.063

4435.063

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

15

4435.0418

4435.0418

Schurter

CIR BRKR THRM 500MA 240VAC 60VDC

9

4435.0347

4435.0347

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

0

4435.0359

4435.0359

Schurter

CIR BRKR THRM 240VAC 32VDC

10

4435.0622

4435.0622

Schurter

CIR BRKR THRM 2.5A 240VAC 32VDC

20

4435.0057

4435.0057

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

10

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top