Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0083

4435.0083

Schurter

CIR BRKR THRM 2.8A 240VAC 32VDC

13

4410.0152

4410.0152

Schurter

CIR BRKR THRM 16A 240VAC 28VDC

20

4400.0165

4400.0165

Schurter

CIR BRKR THRM 500MA 240VAC 48VDC

96

4430.3416

4430.3416

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

15

4430.0038

4430.0038

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

2

4404.0102

4404.0102

Schurter

CIRC BREAKER PCB MNT 10A

1309

4420.0325

4420.0325

Schurter

CIR BRKR THRM MAG 1A 480V 65V

0

4400.0715

4400.0715

Schurter

CIR BRKR THRM 500MA 240VAC 48VDC

0

4430.2304

4430.2304

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

1540

4430.2145

4430.2145

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

39

TS-709-5

TS-709-5

Schurter

CIR BRKR THRM 5A 250VAC 50VDC

125

4420.021

4420.021

Schurter

CIR BRKR THRM MAG 30A 480V 65V

0

4430.2374

4430.2374

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

7

4419.9008

4419.9008

Schurter

CIR BRKR THRM 8A 240VAC 48VDC

0

4430.1559

4430.1559

Schurter

CIR BRKR THRM 18A 240VAC 60VDC

9

4404.0026

4404.0026

Schurter

CIR BRKR THRM 14A 240VAC 48VDC

200

4435.0193

4435.0193

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

10

4420.0282

4420.0282

Schurter

CIR BRKR THRM MAG 16A 480V 65V

0

4435.0365

4435.0365

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

9

4404.0024

4404.0024

Schurter

CIR BRKR THRM 16A 240VAC 48VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure