Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4400.0348

4400.0348

Schurter

CIR BRKR THRM 1.5A 240VAC 48VDC

23

4430.0423

4430.0423

Schurter

CIR BRKR THRM 8A 240VAC 60VDC

15

4430.0022

4430.0022

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

20

4435.018

4435.018

Schurter

CIR BRKR THRM 3A 240VAC 32VDC

0

4400.0716

4400.0716

Schurter

CIR BRKR THRM 2A 240VAC 48VDC

0

4430.1392

4430.1392

Schurter

CIR BRKR THRM 18A 240VAC 60VDC

85

4435.0207

4435.0207

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

9

4430.2305

4430.2305

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

13

4400.0153

4400.0153

Schurter

CIR BRKR THRM 300MA 240VAC 48VDC

0

4435.0322

4435.0322

Schurter

CIR BRKR THRM 4A 240VAC 60VDC

0

4420.0335

4420.0335

Schurter

CIR BRKR THRM MAG 2A 480V 65V

0

TS-701-HT-15-HP

TS-701-HT-15-HP

Schurter

CIR BRKR THRM 15A 250VAC 50VDC

77

4435.0115

4435.0115

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

10

4435.0259

4435.0259

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

10

4430.3115

4430.3115

Schurter

CIR BRKR THRM 13A 240VAC 60VDC

16

4435.0277

4435.0277

Schurter

CIR BRKR THRM 5.5A 240VAC 60VDC

8

4435.0222

4435.0222

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

9

4411.0087

4411.0087

Schurter

CIR BRKR THRM 1A 277VAC 28VDC

14

4435.0361

4435.0361

Schurter

CIR BRKR THRM 20A 240VAC 32VDC

19

4400.0003

4400.0003

Schurter

CIR BRKR THRM 10A 240VAC 48VDC

127

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure