Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4430.2044

4430.2044

Schurter

CIR BRKR THRM 7A 240VAC 60VDC

8

4430.2931

4430.2931

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

3

4420.0273

4420.0273

Schurter

CIR BRKR THRM MAG 3A 480V 65V

5

4435.0247

4435.0247

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

20

4420.0207

4420.0207

Schurter

CIR BRKR THRM MAG 6A 480V 65V

0

4435.0017

4435.0017

Schurter

CIR BRKR THRM 12A 240VAC ROCKER

4

4435.0508

4435.0508

Schurter

CIR BRKR THRM 20A 240VAC 32VDC

20

4435.0424

4435.0424

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

0

4435.0237

4435.0237

Schurter

CIR BRKR THRM 12A 240VAC 32VDC

19

4400.0412

4400.0412

Schurter

CIR BRKR THRM 700MA 240VAC 48VDC

0

4430.3022

4430.3022

Schurter

CIR BRKR THRM 1A 240VAC 60VDC

15

4435.0179

4435.0179

Schurter

CIR BRKR THRM 1A 240VAC 32VDC

10

4404.0098

4404.0098

Schurter

CIRC BREAKER PCB MNT 5A

772100

4435.0362

4435.0362

Schurter

CIR BRKR THRM 2A 240VAC 60VDC

5

4420.0304

4420.0304

Schurter

CIR BRKR THRM MAG 15A 180 VDC

0

4410.0019

4410.0019

Schurter

CIR BRKR THRM 12A 240VAC 28VDC

17

4404.001

4404.001

Schurter

CIR BRKR THRM 15A 240VAC 32VDC

153

4400.0052

4400.0052

Schurter

CIR BRKR THRM 12A 240VAC 48VDC

92

4404.0008

4404.0008

Schurter

CIR BRKR THRM 14A 240VAC 32VDC

92

4435.0293

4435.0293

Schurter

CIR BRKR THRM 2A 240VAC 32VDC

10

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure