Accessories

Image Part Number Description / PDF Quantity Rfq
HVFO100-5X-TIP-U

HVFO100-5X-TIP-U

Teledyne LeCroy

OSCOPE U PROBE X5 60MHZ 10M

15

PK-ZS-002

PK-ZS-002

Teledyne LeCroy

OFFSET GROUND Z LEAD 4/PC

8

WS3K-FG

WS3K-FG

Teledyne LeCroy

FUNCTION GEN SOFTWARE OPTION FOR

0

PK1-5MM-106

PK1-5MM-106

Teledyne LeCroy

SET CODING RINGS

22

PK-ZS-011

PK-ZS-011

Teledyne LeCroy

GROUND BLADE WIDE 4/PC

2

PK007-026

PK007-026

Teledyne LeCroy

11CM GND LD W/MINI CLIP

6

HVFO100-40X-TIP-U

HVFO100-40X-TIP-U

Teledyne LeCroy

UNIV TIP ACCY HVFO10X +/-40V X40

6

PP005-GL22

PP005-GL22

Teledyne LeCroy

22CM PROBE GND LEAD

29

AC032XXA-X

AC032XXA-X

Teledyne LeCroy

MERCURY EXTERNAL TRIGGER CABLE

4

HDO4K-AUTO

HDO4K-AUTO

Teledyne LeCroy

AUTO TRIGGER DECODE OPTION

0

PK-ZS-015

PK-ZS-015

Teledyne LeCroy

GROUND BLADE ZS4000 4/PC

1

PK007-023

PK007-023

Teledyne LeCroy

ADAPTER 4MM PLUG

5

HDO4K-DIGRFV4BUS D

HDO4K-DIGRFV4BUS D

Teledyne LeCroy

DIGRF V4 TRIGGER DECODE OPTION

0

PKIT1-5MM-101

PKIT1-5MM-101

Teledyne LeCroy

MICRO CLIP SET

2

HDO4K-PWR

HDO4K-PWR

Teledyne LeCroy

POWER ANALYSIS OPTION

0

PK30X-2

PK30X-2

Teledyne LeCroy

BANANA ALLIGATOR CLIPS

1

PK-ZS-010

PK-ZS-010

Teledyne LeCroy

CHANNEL ID CLIP 4/PC

6

DX20-PT-KIT

DX20-PT-KIT

Teledyne LeCroy

ADJUSTABLE POSITIONER TIP KIT

0

RP4000-BROWSER-KIT

RP4000-BROWSER-KIT

Teledyne LeCroy

RP4030 350 MHZ BROWSER TIP ACCES

0

RP4000-UFL-PCBMOUNT

RP4000-UFL-PCBMOUNT

Teledyne LeCroy

QTY. 10 U.FL 3MM X 3MM PCB MOUNT

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top